John Deere 003695.02 – ICC: DPF Regeneration Switch Signal Voltage Issue
Issue description
The Instrument Cluster Controller (ICC), or dash module, has detected that the voltage signal from the DPF regeneration switch is outside the expected range (too high, too low, or erratic). This malfunction prevents the operator from properly controlling DPF regeneration functions, such as initiating a parked regeneration or inhibiting the automatic regeneration process.
Applies to these machines
26 machines- 5045E
- 5050E
- 5055E
- 5058E
- 5065E
- 5067E
- 5075E
- 5085E
- 5090E
- 5090EL
- 5100E
- 5075M
- 5085M
- 5100M
- 5100MH
- 5100ML
- 5115M
- 5115ML
- 6100D
- 6105D
- 6110D
- 6115D
- 6125D
- 6130D
- 6140D
- 4940 Sprayer
Check the cause
Visually inspect the DPF regeneration switch for physical damage, such as cracks, breakage, or being stuck in one position
Examine the wiring harness and connectors associated with the regeneration switch for frayed, pinched, or corroded wires
Ensure the switch connector is securely plugged in and that the terminals are clean and free of corrosion
With the key on, check for the correct voltage at the switch's electrical connector (requires model-specific wiring diagram to identify power, ground, and signal wires)
Use a multimeter to test the continuity and resistance of the switch in its different positions to determine if it has an internal failure
Repair steps
Confirm fault code
Access the diagnostic trouble codes through the tractor's display to confirm that ICC 003695.02 is active.
Perform Diagnostic Checks
Follow the diagnostic checks listed above to isolate the cause of the fault.
Repair wiring or connectors
If any issues are found during the visual or voltage checks, repair or replace the damaged wiring harness or connector components.
Replace regeneration switch
If the diagnostic checks point to a faulty switch (e.g., it fails the continuity test), replace the regeneration switch located on the dashboard or control console.
Clear fault code
After the repair is complete, clear the diagnostic trouble code from the ICC's memory.
Verify the repair
Operate the DPF regeneration switch to ensure it is functioning correctly and that the fault code does not reappear.
Parts you might need
(1)Manufactured by Eaton for John Deere. Direct-fit replacement, panel-mounted switch with a pigtail connector designed for a 12-volt system.
Get help to fix this fault by requesting a quote