003696.02
John Deere 003696.02: Signal Voltage Issue From DPF Filter Switch (ICC)
Issue description
The Dash Module has detected an issue with the signal voltage from the DPF Filter Switch (ICC). This indicates a potential problem with the voltage signal being received by the Dash Module from the DPF Filter Switch.
Check the cause
The DPF Filter Switch (ICC)
The wiring or connections to the DPF Filter Switch (ICC)
The power supply or ground connection for the DPF Filter Switch (ICC)
Repair steps
Inspect
Inspect the DPF Filter Switch (ICC) for physical damage or wear.
Check
Check the wiring and connections to the DPF Filter Switch (ICC) for looseness, corrosion, or damage.
Test
Test the power supply and ground connection for the DPF Filter Switch (ICC) to ensure proper operation.
Parts you might need
(0)Get help to fix this fault by requesting a quote