John Deere 003696.02: Signal Voltage Issue From DPF Filter Switch (ICC)

Issue description

The Dash Module has detected an issue with the signal voltage from the DPF Filter Switch (ICC). This indicates a potential problem with the voltage signal being received by the Dash Module from the DPF Filter Switch.

Check the cause

  1. The DPF Filter Switch (ICC)

  2. The wiring or connections to the DPF Filter Switch (ICC)

  3. The power supply or ground connection for the DPF Filter Switch (ICC)

Repair steps

  1. Inspect

    Inspect the DPF Filter Switch (ICC) for physical damage or wear.

  2. Check

    Check the wiring and connections to the DPF Filter Switch (ICC) for looseness, corrosion, or damage.

  3. Test

    Test the power supply and ground connection for the DPF Filter Switch (ICC) to ensure proper operation.