John Deere 3711: DOC Inlet Temperature Fault
Issue description
The fault code indicates an issue related to the temperature at the inlet of the Diesel Oxidation Catalyst (DOC). This may suggest abnormal operating conditions or a malfunction in the system that monitors or controls the inlet temperature.
Check the cause
The temperature sensor located at the DOC inlet
The wiring and connections to the temperature sensor
The component identified by this code
Repair steps
Inspect
Inspect the temperature sensor at the DOC inlet for physical damage or corrosion.
Test
Test the electrical connections and wiring to the temperature sensor for continuity and proper signal transmission.
Verify
Verify the functionality of the component identified by this code using the service manual.