John Deere 003976.03 – RLC: Cab Dome Light High Voltage
Issue description
The Cab Roof Module (RLC) has detected that the voltage in the Cab Dome Light 1 circuit is above the normal operating range. This condition (Voltage Above Normal, or Shorted to High Source) is typically caused by a short circuit to a power source, the installation of an incorrect higher-wattage bulb, or an internal fault within the controlling RLC module itself.
Applies to these machines
23 machines- 4030
- 4230
- 4430
- 4630
- 4040
- 4240
- 4440
- 4640
- 4840
- 50 Series
- 55 Series
- 60 Series
- 6620
- 7720
- 8820
- 2320
- 2420
- 3430
- 3830
- 5720
- 5820
- 5730
- 5830
Check the cause
Cycle the key switch off and on to see if the code clears, as this can resolve temporary RLC-related faults
Inspect the dome light bulb to ensure it is not burnt out and that an incorrect, higher-wattage bulb has not been installed
Test the functionality of the dome light switch in all positions (e.g., ON, OFF, DOOR) to rule out a faulty switch
Check for any blown fuses related to the cab lighting or RLC module
Visually inspect the wiring harness and connectors leading to the dome light and the RLC for chafed, pinched, or corroded wires
Use a multimeter to test for high voltage at the dome light socket and check for continuity in the wiring to identify any short circuits
Repair steps
Disconnect battery
Before beginning any electrical repairs, disconnect the battery's negative terminal to prevent short circuits and ensure safety.
Replace dome light bulb
If the bulb is found to be incorrect or faulty, replace it with the correct OEM-specified bulb.
Replace dome light switch
If the switch is diagnosed as the problem, remove the surrounding trim panels as needed to access and replace the switch.
Repair or replace wiring
If damaged wiring is found, repair the affected section with appropriate connectors and heat shrink tubing, or replace the entire harness section if the damage is extensive.
Replace dome light assembly
If the socket or internal wiring of the dome light assembly is faulty, replace the entire assembly.
Inspect or replace RLC module
If all other components in the circuit test correctly, the fault may lie within the Roof Lighting Control (RLC) module itself. Consult a John Deere dealer for further diagnostics before replacing this component.
Reconnect battery and test
After completing the repairs, reconnect the battery and test the dome light's operation. Check if the fault code has been cleared from the system.
Parts you might need
(9)Dome Light / Interior Light Assembly
AUC11318Dome Light / Interior Light Assembly
AT46718012 or 24 Volts, 10 Watts
Dome Light / Interior Light Assembly
AT32054424 Volts, 10 Watts
Dome Light / Interior Light Assembly (Aftermarket)
MJD40DLAftermarket replacement for 30/40/50/55/60 Series (cross-references to OEM RE10761, AR78418)
Roof Lighting Control (RLC) Module
Part numbers are highly specific to the machine model and configuration. Contact a John Deere dealer with the machine's serial number.
Fits a wide range of 6R series tractors
- Dome Lamp AssemblyAL205771
Fits various 6M and 6R series tractors
- Dome LightAL154760
Specifically noted for 6145R
Get help to fix this fault by requesting a quote