Issue description

The Cab Roof Module (RLC) has detected that the voltage in the Cab Dome Light 1 circuit is above the normal operating range. This condition (Voltage Above Normal, or Shorted to High Source) is typically caused by a short circuit to a power source, the installation of an incorrect higher-wattage bulb, or an internal fault within the controlling RLC module itself.

Applies to these machines

  • 4030
  • 4230
  • 4430
  • 4630
  • 4040
  • 4240
  • 4440
  • 4640
  • 4840
  • 50 Series
  • 55 Series
  • 60 Series
  • 6620
  • 7720
  • 8820
  • 2320
  • 2420
  • 3430
  • 3830
  • 5720
  • 5820
  • 5730
  • 5830

Check the cause

  1. Cycle the key switch off and on to see if the code clears, as this can resolve temporary RLC-related faults

  2. Inspect the dome light bulb to ensure it is not burnt out and that an incorrect, higher-wattage bulb has not been installed

  3. Test the functionality of the dome light switch in all positions (e.g., ON, OFF, DOOR) to rule out a faulty switch

  4. Check for any blown fuses related to the cab lighting or RLC module

  5. Visually inspect the wiring harness and connectors leading to the dome light and the RLC for chafed, pinched, or corroded wires

  6. Use a multimeter to test for high voltage at the dome light socket and check for continuity in the wiring to identify any short circuits

Repair steps

  1. Disconnect battery

    Before beginning any electrical repairs, disconnect the battery's negative terminal to prevent short circuits and ensure safety.

  2. Replace dome light bulb

    If the bulb is found to be incorrect or faulty, replace it with the correct OEM-specified bulb.

  3. Replace dome light switch

    If the switch is diagnosed as the problem, remove the surrounding trim panels as needed to access and replace the switch.

  4. Repair or replace wiring

    If damaged wiring is found, repair the affected section with appropriate connectors and heat shrink tubing, or replace the entire harness section if the damage is extensive.

  5. Replace dome light assembly

    If the socket or internal wiring of the dome light assembly is faulty, replace the entire assembly.

  6. Inspect or replace RLC module

    If all other components in the circuit test correctly, the fault may lie within the Roof Lighting Control (RLC) module itself. Consult a John Deere dealer for further diagnostics before replacing this component.

  7. Reconnect battery and test

    After completing the repairs, reconnect the battery and test the dome light's operation. Check if the fault code has been cleared from the system.

Parts you might need

(9)
  • Dome Light / Interior Light Assembly

    AUC11318
  • Dome Light / Interior Light Assembly

    AT467180
  • 12 or 24 Volts, 10 Watts

  • Dome Light / Interior Light Assembly

    AT320544

    24 Volts, 10 Watts

  • Dome Light / Interior Light Assembly (Aftermarket)

    MJD40DL

    Aftermarket replacement for 30/40/50/55/60 Series (cross-references to OEM RE10761, AR78418)

  • Roof Lighting Control (RLC) Module

    Part numbers are highly specific to the machine model and configuration. Contact a John Deere dealer with the machine's serial number.

  • Fits a wide range of 6R series tractors

  • Fits various 6M and 6R series tractors

  • Dome LightAL154760

    Specifically noted for 6145R

Get help to fix this fault by requesting a quote

Browse other John Deere codes