John Deere 4334.16 – Engine Control Unit (ECU): DEF Dosing Unit Pressure Moderately High
Issue description
The DEF dosing unit pressure is detected to be moderately high. This typically happens when the DEF dosing unit fails to relieve system pressure during a shut-off sequence or during a new suction sequence, causing improper DEF dosing and negatively affecting the performance of the aftertreatment system.
Applies to these machines
34 machines- 5085E
- 5090E
- 5090EL
- 5100E
- 5090M
- 5100M
- 5100MH
- 5100ML
- 5115M
- 6110M
- 6120M
- 6130M
- 6145M
- 6155M
- 6175M
- 6195M
- 6110R
- 6120R
- 6130R
- 6145R
- 6155R
- 6175R
- 6195R
- 6215R
- 9470RT
- 9520RT
- 9570RT
- 8245R through 8400R
- 6105M
- 5085M
- 5095M
- 5105M
- Vermeer D24x40 S3
- Vermeer D40x55 S3
Check the cause
Inspect the DEF dosing unit and all associated lines for physical blockages, kinks, or malfunctions that could prevent pressure relief
Ensure that the pressure relief mechanism/valve inside the DEF dosing unit is functioning correctly
Inspect the DEF fluid for dirt, debris, or crystallization that could be causing pressure blockages
Use a diagnostic tool to monitor the DEF pressure sensor live data to ensure it is providing accurate readings and not defaulting to a falsely high value
Repair steps
Preparation
Turn off the machine, disconnect the batteries, and allow the aftertreatment system to cool and depressurize.
Clear Blockages
If any DEF lines were found to be kinked or blocked during diagnosis, clean or replace the affected lines.
Address Contamination
If the DEF fluid is contaminated, drain the DEF tank, flush the system, replace the DEF pump filter, and refill with fresh, high-quality Diesel Exhaust Fluid.
Replace Faulty Sensor
If diagnostic testing proved the DEF pressure sensor is reading falsely high, replace the sensor.
Replace DEF Dosing Unit
If the lines are clear, the sensor is accurate, and the unit still fails to relieve pressure internally during shut-off/suction sequences, the internal pressure relief mechanism has failed. You will need to replace the DEF Dosing Unit Pump assembly.
Reassembly and Reset
Reconnect the batteries. Use a diagnostic tool to reset the ECU and clear the 004334.16 fault code.
Validation
Run the machine through a standard operating cycle and monitor the DEF system pressure to ensure normal operation and verify the code does not return.
Parts you might need
(13)DEF Dosing Unit Pump (2.2 EVO / NRV)
DZ128067Replaces DZ121770
DEF Dosing Unit Pump (2.2 EVO / NRV)
DZ121770Replaced by DZ128067
DEF Dosing Unit Pump (2.2 EVO / NRV)
DZ111284DEF Dosing Unit Pump (2.2 EVO / NRV)
DZ111283DEF Dosing Unit Pump (2.2 EVO / NRV)
RE553796DEF Dosing Unit Pump (2.2 EVO / NRV)
MIA885343DEF Dosing Unit Pump (2.2 EVO / NRV)
0444042067Bosch cross-reference
DEF Dosing Unit Pump (2.2 EVO / NRV)
0444042182Bosch cross-reference
DEF Pressure Sensor
RE557767DEF Pressure Sensor
0281006119Bosch cross-reference
DEF Pressure Sensor
0-281-006-119Bosch cross-reference
Diesel Exhaust Fluid (DEF) Injection Pump Filter Kit
DZ114640DEF Dosing Injection Nozzle
RE560468
Get help to fix this fault by requesting a quote