522280.13

John Deere 522280.13 – BRC: Auxiliary System Fault (Secondary Brake Pressure Not Calibrated)

Issue description

A fault has been detected in the auxiliary brake system indicating that the secondary brake pressure is not calibrated. The sensor measuring pressure in the secondary brake circuit is providing readings outside the expected range, or the Brake Control Unit (BRC) has lost its calibration memory for this sensor. Because the secondary brake system is a critical safety component, this fault can cause the braking system to be derated or rendered completely inoperable until resolved. The display may show messages such as 'Secondary Brake System Not Calibrated' or 'Brake System Inoperable'.

Applies to these machines

  • 8130
  • 8230
  • 8330
  • 8430
  • 8530
  • 9230
  • 9330
  • 9430
  • 9530
  • 9630

Check the cause

  1. Cycle the tractor power using the key switch to see if the intermittent fault clears

  2. Put the vehicle in Park with the engine running and cycle the secondary brake lever

  3. Visually inspect the wiring harnesses and connections between the Brake Control Unit (BRC) and the secondary brake pressure sensor for damage, corrosion, or loose connections

  4. Check for other active fault codes that could pinpoint the root cause, such as sensor voltage codes (BRC 522280.03, BRC 522280.04) or control valve codes (BRC 522279.13)

Repair steps

  1. Perform dealer calibration

    The secondary brake pressure sensor must be calibrated by a qualified John Deere dealer using specialized proprietary diagnostic tools and software to set the zero-pressure and known-pressure points.

  2. Replace secondary brake pressure sensor

    If calibration fails or the dealer diagnoses a faulty sensor, replace the secondary brake pressure sensor or transducer.

  3. Replace secondary brake switch

    If the sensor is functioning but the fault persists, replace the secondary brake switch based on dealer diagnosis.

  4. Replace Brake Control Unit (BRC)

    If all external components and wiring are verified and the controller cannot retain calibration, replace the Brake Control Unit.