Skip to main content
522343.09

John Deere 522343.09 – ATC: R17 Resistor at Heated Rear Window, Incorrect CAN BUS Message from ATC (Power Module (HF) PC6)

Issue description

This fault code is generated when there is a data transfer problem between the Power Module (HF) PC6 and the Automatic Temperature Control (ATC) unit. Specifically, the reception of one, several, or all of the CAN messages transmitted by the ATC to the power module is intermittent or nonexistent. This intermittent reception is most commonly caused by a loose wire or poor connection.

Applies to these machines

  • 6230 Premium
  • 6330 Premium
  • 6430 Premium
  • 7130 Premium
  • 7230 Premium
  • 7330 Premium
  • 7430 Premium
  • 7530 Premium

Check the cause

  1. Check for additional diagnostic trouble codes from other control units (such as BCU 002354.09, BCU 002386.09, BCU 523691.09, or BIF 522426.09) that relate to CAN BUS message transfers at the power module, as these take priority and indicate a broader CAN BUS issue.

  2. Perform the CAN BUS Check with CommandCenter (DTI) via the tractor's diagnostic interface to verify network integrity.

  3. Thoroughly inspect the wiring harness and connectors between the ATC control unit and the Power Module (HF) PC6 for backed-out pins, corrosion, or chafed wires.

Repair steps

  1. Access the modules

    Locate the ATC control unit and the Power Module (HF) PC6, which are often located in the roof or cab area depending on the exact tractor configuration.

  2. Inspect and clean connectors

    Disconnect the wiring harness connectors at both the ATC and the Power Module PC6. Inspect for moisture, corrosion, or loose terminals. Clean the contacts with electrical contact cleaner.

  3. Test harness continuity

    Using a multimeter, perform a continuity test on the CAN BUS communication lines between the ATC and the Power Module PC6 to isolate any open circuits or high resistance.

  4. Repair wiring

    If a loose wire or damaged harness is found, repair or replace the affected wiring section.

  5. Replace faulty component

    If the wiring harness tests perfectly, the fault may lie internally within the Power Module (HF) PC6 or the ATC unit failing to send or receive the CAN messages. Replace the faulty module.

  6. Clear and retest

    Reconnect all components, clear the diagnostic trouble codes via the CommandCenter, and cycle the heated rear window switch to verify the code does not return.