John Deere 523316.04 – CCU (Chassis Control Unit): CCU Switched Supply Voltage Low
Issue description
The switched 12-volt power supply to the control unit has dropped below the normal operating threshold, specifically falling below 9.0 volts. This low voltage condition can impair the functionality of the module, leading to potential issues in managing and controlling various vehicle systems.
Applies to these machines
26 machines- 5085E
- 5090E
- 5090EL
- 5100E
- 5045E
- 5055E
- 5065E
- 5075E
- 5085M
- 5100M
- 5100MH
- 5100ML
- 5115ML
- 5090M
- 5115M
- 5083E
- 5093E
- 5095M
- 5105M
- 8310RT
- 8335RT
- 8360RT
- 9330
- 9430
- 9530
- 9630
Check the cause
Inspect the battery and alternator to ensure they are providing adequate power to the machine
Examine all wiring and electrical connections leading to the CCU for damage, corrosion, or looseness that could cause voltage drops
Use a multimeter to measure the voltage directly at the CCU terminals to confirm the low voltage condition and identify where the voltage drop is occurring
Investigate any potential parasitic electrical draws that might be draining power from the system when the machine is off
Repair steps
Address the Power Source
If the battery is weak or not holding a charge, replace it. If the alternator is failing to maintain system voltage, repair or replace the alternator.
Repair the Circuit
Clean and tighten all battery terminals and chassis grounds. Repair or replace any damaged wiring, corroded connectors, or faulty relays/fuses in the switched power circuit supplying the CCU.
Reset and Recalibrate
After resolving the electrical supply issues, clear the fault codes. Reset the CCU and recalibrate the system if needed to ensure proper operation.
Parts you might need
(8)Electronic Control Unit
RE218346fits select 5E / 5EN / 5EL series
Chassis Central Control Unit Module
RE170416Equipment Electronic Control Unit
SJ29032012V Battery
Alternator
Relays
Fuses
Wiring Harness connectors