John Deere 523695.09 – SCC / SCO / SCU: Missing SCV V External Control Message for 1 Second
Issue description
CAN bus communication failure. The control module has not received the expected command data from the Selective Control Valve (SCV) #5 external control lever (or external implement connection) via the CAN bus for a duration of more than 1 second.
Applies to these machines
26 machines- 6110R
- 6120R
- 6130R
- 6145R
- 6155R
- 6175R
- 6195R
- 6215R
- 8235R
- 8245R
- 8260R
- 8310R
- 8310RT
- 8335RT
- 8360RT
- 8400R
- 9230
- 9330
- 9430
- 9530
- 9630
- 7720
- 7820
- 7920
- 7715
- 7815
Check the cause
Restart the tractor to see if the temporary communication glitch resets upon startup
Check external implement connections at SCV V to ensure the harness is properly plugged in, securely seated, and free of dirt or debris
Visually inspect the CAN bus wiring between the SCV V external control lever and the SCC/SCO module for chafing, breaks, or corrosion
Ensure the connector pins at the SCV V lever and the SCC module are fully seated and not bent or corroded
Repair steps
Power Down
Turn off the tractor, remove the key, and disconnect the battery to prevent electrical shorts during inspection.
Implement Disconnect
Disconnect and clean any external implement connections related to SCV V. Apply dielectric grease and reconnect.
Harness Inspection
Locate the harness connector at the SCV V control lever and the SCC/SCO module. Disconnect both ends and inspect for moisture, pushed-out pins, or corrosion. Clean with electrical contact cleaner.
Continuity Testing
Using a multimeter, perform a continuity test on the CAN High and CAN Low wires between the SCV V lever and the module. Check for open circuits or shorts to ground/power. Repair or replace the harness if a fault is found.
Reassembly and Testing
Reconnect all components, restore battery power, and restart the tractor. Operate the SCV V lever to see if the code returns.
Component Replacement
If the wiring is intact and the code persists, the SCV V control lever (sensor/switch) or the SCC module itself is likely faulty. Replacement of these modules may require a John Deere dealer to perform a software calibration or GreenStar system update.
Parts you might need
(3)SCV V External Control Lever / Switch
Fitment: Cab controls / Armrest
CAN Bus Wiring Harness / Connector Repair Kit
Fitment: SCV to SCC circuit
SCC / SCO / SCU Control Module
Fitment: Chassis/Hydraulic control unit
Get help to fix this fault by requesting a quote