John Deere 523701.06 – HCC / BCU: M08 Stepper Motor for the Hitch (Coil 2) Current Too High
Issue description
Current at the outputs to the M08 Stepper Motor for the Hitch (Coil 2) on leads 7054 and 7055 is excessively high, indicating a short to ground. This overcurrent condition can lead to overheating, component damage, or a fire hazard, causing the system to limit or shut down power to the affected circuit and impairing rear hitch operation.
Applies to these machines
45 machines- 6110M
- 6120M
- 6130M
- 6145M
- 6155M
- 6175M
- 6195M
- 6110R
- 6120R
- 6130R
- 6145R
- 6155R
- 6175R
- 6195R
- 6215R
- 5090M
- 5100M
- 5100MH
- 5100ML
- 5115M
- 6M-1654
- 6M-1854
- 6M-2104
- 6230R
- 6250R
- 6230
- 6330
- 6430
- 5080R
- 5090R
- 5100R
- 5080RN
- 5090RN
- 5100RN
- 6145J
- 6165J
- 6180J
- 6205J
- 6210J
- 6090MC
- 6100MC
- 6110MC
- 6090RC
- 6100RC
- 6110RC
Check the cause
Inspect wiring harness and connectors specifically for leads 7054 and 7055 (routing to the M08 Stepper Motor) for damage, wear, melted insulation, or fraying that could cause a short to ground
Measure current flow through leads 7054 and 7055 using a clamp meter or multimeter to confirm the active overcurrent condition
Test the internal resistance of the M08 stepper motor (specifically Coil 2) to see if the motor has failed internally and is causing the high current draw
Repair steps
Isolate the Short
Based on the diagnostic checks, locate the exact point of the short to ground within the circuit.
Repair Wiring
If the short is in the harness, repair or replace the damaged wires or connectors. Ensure all wiring is correctly insulated and routed away from pinch points or high-heat areas to prevent future shorts.
Replace the Motor/Valve
If the wiring is intact but Coil 2 inside the stepper motor has failed (shorted internally), replace the M08 Stepper Motor / Rear Hitch Control Valve assembly.
Reset the Control Unit
After addressing the short circuit and making necessary repairs, reset the BCU or HCC to clear the diagnostic trouble code and reinitialize the system settings.
Test Hitch Operation
Conduct a functional test of the hitch control system. Command the hitch to raise and lower to ensure that the stepper motor operates correctly without triggering the overcurrent code.
Parts you might need
(4)Rear Hitch Control Valve
AL232083Fits most 6M and 6J series tractors
Rear Hitch Control Valve
AL212972Fits most 6R and 6RC series tractors
Rear Hitch Control Valve
SJ41707Replaces older part number SJ35929
Rear Hitch Control Valve
SJ35929Older part number, replaced by SJ41707
Get help to fix this fault by requesting a quote