John Deere 523811.05 – RPT or BCU: Rear PTO Speed 1 Solenoid Low Amp Draw
Issue description
The control software measures a current of less than 500 mA at the output to the PTO Speed 1 solenoid (Y73) while it is activated, indicating an open circuit. This limits or disables rear PTO functionality.
Applies to these machines
11 machines- 6110R
- 6120R
- 6130R
- 6145R
- 6155R
- 6175R
- 6195R
- 6215R
- 6230
- 6330
- 6430
Check the cause
Inspect the wiring harness and connections leading to the Y73 PTO Speed 1 solenoid for signs of an open circuit, chafed wires, or disconnected plugs.
Check for bent pins inside the solenoid connector that may prevent a solid electrical connection.
Use a multimeter or John Deere diagnostic tools to measure the current levels at the solenoid. Ensure the current is above 500 mA when the solenoid is commanded on.
Test the Y73 solenoid directly to ensure it operates properly when adequate current is applied.
Repair steps
Repair Wiring/Connectors
If the diagnostic checks reveal bent pins, corrosion, or broken wires, install a new connector and pins on the wiring harness, or repair the broken wire.
Replace the Solenoid
If the wiring is intact but the Y73 solenoid fails direct operational testing or has an internal open circuit, remove and replace the PTO Speed 1 solenoid.
Update Control Software
Ensure that the PAP (or BCU) control software is updated to the latest version. Apply any available patches from John Deere that address current regulation or communication issues.
Clear Codes and Test
Clear the 523811.05 code and engage the Rear PTO to verify that the system is fully functional and the code does not return.
Parts you might need
(2)PTO Solenoid Valve
AL177192Fits John Deere 6R, 6M, and 30-series tractors including 6110R-6190R, 6230, 6330, 6430
PTO Solenoid
AL158332Fits older 6020, 6030, and 6010 series tractors
Get help to fix this fault by requesting a quote