523813.11

John Deere 523813.11 – RPT (Rear Chassis): Solenoid for PTO Speed 1, Fault

Issue description

The system detects a circuit fault in the solenoid responsible for PTO speed 1, typically a shorted circuit, an open circuit, or an overheating solenoid, causing the rear PTO to be significantly limited or entirely non-functional.

Applies to these machines

  • 6110R
  • 6120R
  • 6130R
  • 6145R
  • 6155R
  • 6175R
  • 6195R
  • 6215R

Check the cause

  1. Visually and physically inspect the wiring harness and connections leading to the PTO speed 1 solenoid for signs of a short, open circuit, or heat damage

  2. Measure current and voltage levels at the PTO speed 1 solenoid using a multimeter to ensure they are within the specified operating range

  3. Actively test the solenoid for proper operation using John Deere Service ADVISOR diagnostic tools

  4. Check if the PAP control software is updated to the latest version to rule out false circuit faults

Repair steps

  1. Wiring Repair

    If the diagnostic checks reveal damaged wires or connectors, repair or replace the affected sections of the wiring harness.

  2. Solenoid Replacement

    If the wiring and voltage are correct but the solenoid fails the operational test or is physically overheating, remove and replace the faulty PTO solenoid valve.

  3. Software Update

    Apply any available software updates to the PAP control module.

  4. Clear and Verify

    Clear the RPT 523813.11 fault code from the system and test the rear PTO engagement to verify the repair.

Parts you might need

(1)
  • PTO Solenoid Valve (Front/Rear PTO)

    AL177192

    Fits a wide range of John Deere tractors including the 6R series (6105R through 6250R), 6M series, 6D series, and 6E series.

Get help to fix this fault by requesting a quote