523888.04

John Deere 523888.04 – SIC: A37 - Stepper Motor E-SCV 2, Temperature Too Low

Issue description

The temperature reading of the stepper motor for E-SCV 2 drops below 45°C (49°F), which usually indicates an open circuit, a failed internal temperature sensor within the stepper motor, or a wiring harness issue.

Applies to these machines

  • 6110R
  • 6120R
  • 6130R
  • 6145R
  • 6155R
  • 6175R
  • 6195R
  • 6215R
  • 6220
  • 6320
  • 6420
  • 6230
  • 6330
  • 6430
  • 6820
  • 6920
  • 6930
  • 6110M
  • 6120M
  • 6130M
  • 6145M
  • 6155M
  • 6175M
  • 6195M
  • 6230R
  • 6250R
  • 5090R
  • 5100R
  • 5115R
  • 5125R

Check the cause

  1. Inspect harness W32 (the stepper motor wiring harness) for chafing, breaks, or melted insulation.

  2. Disconnect the 4-pin plug (X465) at the E-SCV 2 stepper motor (Component A37) and inspect the pins for corrosion, moisture, or pushed-out terminals.

  3. Use a multimeter to check for continuity between the SIC controller and the X465 connector to rule out a broken wire in the CAN-BUS or power supply lines.

  4. Ensure you do not also have code 523888.18 active, which indicates low supply voltage combined with low hydraulic oil temperature.

Repair steps

  1. Relieve Hydraulic Pressure

    Turn off the tractor and cycle the hydraulic controls to relieve any trapped pressure in the SCV block before beginning work.

  2. Disconnect the Motor

    Unplug the 4-pin electrical connector (X465) from the E-SCV 2 stepper motor.

  3. Remove the Stepper Motor

    Unbolt the faulty stepper motor (A37) from the E-SCV 2 valve slice on the rear hydraulic block.

  4. Install the New Motor

    Mount the replacement stepper motor to the valve block and torque the mounting bolts to OEM specifications.

  5. Reconnect Wiring

    Plug the X465 connector back into the new motor.

  6. Calibrate the Valve

    Connect John Deere Service ADVISOR (or use the tractor's onboard CommandCenter diagnostic interface if equipped). Navigate to the SIC module and perform the E-SCV calibration procedure so the controller can learn the end-stops of the new stepper motor.

  7. Test Operation

    Start the tractor, warm up the hydraulic oil, and actuate SCV 2 to ensure smooth operation and verify the fault code has cleared.

Parts you might need

(2)
  • E-SCV Stepper Motor

    AL234434

    Supersedes older part numbers such as AL223233 and AL219124. Fits the E-SCV valve stack on 5R, 6M, 6R, and 6030 Premium series tractors.

  • SCV Flange Seal Kit

    AL207509

    Recommended when removing and installing components on the valve block to prevent hydraulic leaks.

Get help to fix this fault by requesting a quote