523888.18

John Deere 523888.18 – SIC: Stepper Motor E-SCV 2 (Electro-Hydraulic Selective Control Valve 2) – Hydraulic Oil Temperature and Supply Voltage Too Low

Issue description

The SIC controller has detected that the system voltage at the stepper motor of E-SCV 2 (Component A37) has dropped too low (specifically between 9 and 11 volts) while the hydraulic oil temperature is also cold (typically below 25°C / 13°F).

Applies to these machines

  • 6110R
  • 6120R
  • 6130R
  • 6145R
  • 6155R
  • 6175R
  • 6195R
  • 6215R
  • 6030 Premium Series
  • 6230
  • 6330
  • 6430
  • 6530
  • 6630
  • 6830
  • 6930
  • 7030 Premium Series
  • 7130
  • 7230
  • 7330
  • 7430
  • 7530
  • 6M Series
  • 6R Series

Check the cause

  1. Wait until the hydraulic oil has warmed up to operating temperature (above 25°C / 13°F)

  2. Test the battery voltage and alternator output to ensure the charging system is healthy and voltage at the stepper motor does not drop below 11 volts

  3. Inspect the wiring harness and electrical connector at the E-SCV 2 stepper motor (Component A37) for corrosion, loose pins, or damaged wires

  4. Check ISOBUS connections between the tractor and implement, especially if Tractor-Implement Automation is deactivated

Repair steps

  1. Warm up hydraulic oil and clear codes

    Start the tractor and allow the hydraulic oil to reach normal operating temperature. Clear the codes to see if SIC 523888.18 returns.

  2. Check voltage at stepper motor

    If the code persists, use a multimeter to back-probe the connector at the E-SCV 2 stepper motor. Verify that it is receiving full system voltage (12V+).

  3. Repair wiring harness

    If voltage is low at the connector, trace the harness back to the SIC controller to repair the short, break, or corroded ground causing the voltage drop.

  4. Replace stepper motor

    If the voltage is correct, the hydraulic oil is warm, and the ISOBUS connection is secure, the E-SCV 2 stepper motor itself has likely failed internally and must be replaced.

  5. Calibrate new valve

    After replacing the stepper motor, use a John Deere Service ADVISOR tool to perform the 'E-SCV 2 Stepper Motor A37, Operational Check' and calibrate the new valve.

Parts you might need

(5)
  • Electric Stepper Motor / E-SCV Stepper Motor

    AL209249

    Substituted by AL243656

  • Electric Stepper Motor / E-SCV Stepper Motor

    AL243656

    Substitute for AL209249

  • Electric Stepper Motor / E-SCV Stepper Motor

    AL229568

    Substituted by AL234434

  • Electric Stepper Motor / E-SCV Stepper Motor

    AL234434

    Substitute for AL229568

  • Electric Stepper Motor / E-SCV Stepper Motor

    AL219124

    Depending on the specific valve block generation

Get help to fix this fault by requesting a quote