523905.17

John Deere 523905.17 – PTF: Front PTO Solenoid Valve, Open Circuit

Issue description

The control software detects an open circuit to the front Power Take-Off (PTO) solenoid valve. This typically means that the current in the ground lead or positive lead of the front PTO solenoid valve is too low or completely disconnected, preventing the solenoid from engaging the PTO.

Applies to these machines

  • 6110M
  • 6120M
  • 6130M
  • 6145M
  • 6155M
  • 6175M
  • 6195M
  • 6110R
  • 6120R
  • 6130R
  • 6145R
  • 6155R
  • 6175R
  • 6195R
  • 6215R
  • 6190R
  • 6210R
  • 6230R
  • 6250R
  • 6090MC
  • 6095MC
  • 6100MC
  • 6105MC
  • 6110MC
  • 6115MC
  • 6090RC
  • 6095RC
  • 6100RC
  • 6105RC
  • 6110RC
  • 6115RC

Check the cause

  1. Inspect the wiring harness and all relevant connectors related to the front PTO solenoid valve circuit for damage, corrosion, or loose pins

  2. Verify that the ground connections for the front chassis control unit and the solenoid are secure and free of corrosion

  3. Inspect the solenoid valve circuit to ensure proper voltage levels are reaching the positive lead when the PTO switch is activated

  4. Check the front PTO switch in the cab for correct operation to ensure it is providing plausible values to the module

  5. Ensure the OIC (Operator Interface Control) and PTF control software are up to date

Repair steps

  1. Preparation

    Park the tractor on a level surface, turn off the engine, remove the key, and relieve any residual hydraulic pressure.

  2. Locate the Solenoid

    Locate the front PTO solenoid valve assembly on the front chassis/transmission block.

  3. Disconnect Electricals

    Carefully unplug the electrical wiring harness connector from the PTO solenoid valve.

  4. Remove the Faulty Valve

    Unbolt and remove the old solenoid valve assembly. Be prepared with a catch pan, as a small amount of hydraulic fluid may leak.

  5. Clean and Prep

    Clean the mounting surface thoroughly to prevent dirt from entering the hydraulic system.

  6. Install the New Valve

    Install the replacement PTO solenoid valve, ensuring that all O-rings and seals are properly seated. Bolt it securely into place.

  7. Reconnect and Test

    Reconnect the electrical harness. Start the tractor and test the front PTO engagement several times to confirm the fault code is cleared and the PTO operates smoothly.

Parts you might need

(3)
  • Front/Rear PTO Solenoid Valve Assembly

    AL177192

    Primary OEM Part Number (Fits most 6M, 6R, and 6RC series tractors)

  • Front/Rear PTO Solenoid Valve Assembly

    AL114093

    Alternative/Related OEM Part Number

  • Front/Rear PTO Solenoid Valve Assembly

    RE159087

    Alternative/Related OEM Part Number

Get help to fix this fault by requesting a quote