John Deere SCO523937.06 – SCO: SCV V Retract Solenoid Circuit Current High
Issue description
The Secondary Hydraulic Control Unit (SCO) has detected an abnormally high electrical current in the circuit for the solenoid that controls the retraction of the fifth selective control valve (SCV V). This high current condition is typically caused by a short circuit in the wiring harness or a faulty solenoid coil.
Applies to these machines
17 machines- 9230
- 9330
- 9430
- 9530
- 9630
- 9230 Scraper
- 9330 Scraper
- 9430 Scraper
- 9530 Scraper
- 9630 Scraper
- 7720
- 7820
- 7920
- 7630
- 7730
- 7830
- 7930
Check the cause
Restart the tractor to see if cycling the power clears a temporary communication glitch
Visually inspect the area around the batteries and alternator for any signs of damage or debris accumulation
Check fuse F29 (associated with SCO supply voltage, SCV V, and front hitch valve solenoids), as well as fuses F12, F24, and F51 for the SCV control unit
Inspect for hydraulic contamination and clean the area around the solenoid before removal to prevent dirt from entering the system
After removing the solenoid, inspect the pilot valve for any metal filings or debris that could be causing it to stick, ensuring the pin moves freely
Perform a resistance test on the solenoid's two terminals using a multimeter to check for an out-of-spec reading indicating a faulty coil
Swap the suspect solenoid with a known good one from another SCV to determine if the problem follows the solenoid or stays with the valve
Repair steps
Relieve hydraulic pressure
Shut down the tractor and relieve any pressure in the hydraulic system before beginning work.
Clean the area
Thoroughly clean the area around the SCV solenoid to prevent dirt from entering and contaminating the hydraulic system.
Remove the solenoid
Disconnect the electrical connector from the solenoid. Remove the screws holding the solenoid to the valve body and carefully pull it off.
Inspect and clean the pilot valve
Inspect the pilot valve for any metal filings or debris that could cause it to stick. Ensure the pin in the valve moves freely. Clean with a suitable parts cleaner if necessary.
Install the new solenoid
Place the new solenoid onto the valve body and secure it with the mounting screws. Reconnect the electrical connector.
Flush the system
Run the engine for a few minutes to flush the hydraulic system after installing the new solenoid.
Recalibrate the SCV
Recalibrate the SCV. Note that this procedure may require specialized tools and software available to John Deere technicians.
Parts you might need
(4)- Solenoid ValveRE163491
OEM John Deere solenoid valve compatible with 9x30, 7x20, and 7x30 series tractors
- Solenoid ValveRE233163
OEM John Deere solenoid valve compatible with 9x30 series tractors
- Solenoid ValveRE324802
Aftermarket solenoid valve for 9x30 series tractors
- Hydraulic Control Valve SolenoidRE183407
Compatible with 7720, 7820, 7920, and 7730 models
Get help to fix this fault by requesting a quote