005246.15

John Deere 005246.15 – ECU: Aftertreatment SCR Operator Inducement

Issue description

This fault code indicates an Aftertreatment SCR Operator Inducement. It is a final warning logged by the Engine Control Unit (ECU) signifying that a primary fault within the Selective Catalytic Reduction (SCR) system has been active for an extended period. The ECU forces an engine derate (reduction in performance) to prevent aftertreatment system damage and maintain legal emissions limits. The FMI 15 designation indicates the controller is receiving a valid signal that is above the expected normal range.

Applies to these machines

  • 9470RT
  • 9520RT
  • 9570RT
  • G-Series Excavators
  • P-Series Excavators
  • loaders
  • dozers
  • industrial engines

Check the cause

  1. Retrieve all active and inactive fault codes from the ECU using a diagnostic scanner (e.g., John Deere Service Advisor) to identify the primary root cause

  2. Check for associated SCR/DEF companion faults, such as issues with DEF pressure, DEF quality, DEF level sensors, and NOx sensors

  3. Visually confirm the DEF level in the tank is sufficient and not overfilled

  4. Ensure DEF quality is clean, free of contamination, and from a sealed source. Drain and replace if questionable

  5. Inspect all aftertreatment wiring harnesses and connectors for damage, corrosion, or loose connections

  6. Inspect DEF lines and filters for clogs, crystallization, or physical damage

Repair steps

  1. Diagnose and repair primary fault

    Based on the other active fault codes found, perform the specific diagnostic and repair procedures for that component. This could involve replacing a faulty DEF pump, dosing injector, DEF level/quality sensor, NOx sensor, or repairing damaged wiring.

  2. Clear fault codes

    Once the underlying issue has been repaired, use a diagnostic tool to clear all fault codes from the ECU.

  3. Perform SCR system reset

    Perform a specific 'SCR Faults Reset' or 'Reset Aftertreatment System' procedure using a diagnostic tool. This confirms to the ECU that the repair has been made and allows the system to return to normal operation.

  4. Confirm the repair

    Perform a test drive or a forced regeneration of the aftertreatment system to ensure that the fault code does not return and the engine is no longer in a derate condition.

Parts you might need

(9)
  • Verify fitment by serial number

  • DEF Dosing Supply Module

    8982264732

    Compatible with various John Deere G- and P-series excavators

  • Verify fitment by serial number

  • DEF Line

    DZ125167

    Verify fitment by serial number

  • DEF Line

    DZ129491

    Verify fitment by serial number

  • DEF Line

    RE567857

    Verify fitment by serial number

  • DEF Tank Heating Hose

    AL212188

    Verify fitment by serial number

  • NOx Sensor

    Various aftermarket and OEM options available depending on engine model

  • DEF Pump Repair Harness

    For Bosch-style DEF pumps used in these systems

Get help to fix this fault by requesting a quote