628.13

John Deere 628.13 – EIC / EPC / MDU: Control Unit Internal Fault

Issue description

The module has registered an internal electronic malfunction or noted an internal issue when booting up. This means the hardware or the internal software configuration of the module itself is failing to initialize properly.

Applies to these machines

  • 6110M
  • 6120M
  • 6130M
  • 6145M
  • 6155M
  • 6175M
  • 6195M
  • 6110R
  • 6120R
  • 6130R
  • 6145R
  • 6155R
  • 6175R
  • 6195R
  • 6215R
  • 5085E
  • 5090E
  • 5090EL
  • 5100E
  • 5085M
  • 5095M
  • 5095MH
  • 5105M
  • 5015ML
  • 5100M
  • 5115M
  • 5080R
  • 5090R
  • 5100R
  • 5080RN
  • 5090RN
  • 5100RN
  • 6230
  • 6330
  • 6430
  • 250D
  • 300D
  • 350D
  • 400D

Check the cause

  1. Power Cycle: Restart the tractor to see if the boot-up issue is a temporary glitch. Check if the code transitions from active to stored, or if other codes are present.

  2. Visual Inspection: Inspect the EIC/EPC control unit and its wiring harness for any signs of physical damage, moisture intrusion, or burnt components.

  3. Software Verification: Connect John Deere Service ADVISOR to ensure the control unit is running the latest software version. An outdated or corrupted software file can cause boot-up failures.

  4. Interference Check: Inspect the surrounding environment and wiring for potential sources of electromagnetic interference that could affect the control unit's operation.

Repair steps

  1. Disconnect battery

    Disconnect the machine's battery to prevent electrical arcing.

  2. Access module

    Gain access to the affected module (e.g., remove the dashboard trim to access the EIC Instrument Cluster, or locate the EPC module depending on the machine).

  3. Disconnect wiring

    Disconnect the wiring harness connectors from the faulty module.

  4. Remove control unit

    Unbolt and remove the failed control unit.

  5. Install replacement module

    Install the replacement module and securely reconnect the wiring harnesses.

  6. Reconnect battery

    Reconnect the battery.

  7. Program and calibrate module

    Connect John Deere Service ADVISOR. A new EIC or EPC module will require programming, configuration to the specific tractor's options, and calibration (such as transmission calibrations for the EPC) before the machine will operate correctly.

  8. Clear codes and test

    Clear all stored fault codes and test the machine's operation.

Parts you might need

(8)
  • Instrument Cluster / Main Control Module (EIC) OR Electronic Powertrain Control Unit (EPC)

    Generic Part Name

  • Instrument Panel Cluster

    SJ33424

    Fitment varies heavily by specific 5E models like 5090E, cab vs. open operator station, and transmission type

  • Instrument Panel Cluster

    SJ40133

    Fitment varies heavily by specific 5E models like 5090E, cab vs. open operator station, and transmission type

  • Instrument Panel Cluster

    SJ10521

    Fitment varies heavily by specific 5E models like 5090E, cab vs. open operator station, and transmission type

  • Instrument Panel Cluster

    SJ22550

    Fitment varies heavily by specific 5E models like 5090E, cab vs. open operator station, and transmission type

  • Instrument Cluster

    RE245291

    Common on 5M series such as the 5085M and 5095M

  • Instrument Cluster

    RE283240

    Common on 5M series such as the 5085M and 5095M

  • Instrument Cluster

    SJ13498

    Common on 5M series such as the 5085M and 5095M

Get help to fix this fault by requesting a quote