000629.12

John Deere 000629.12 – ACU: ACU Internal Software Configuration Fault

Issue description

The Armrest Control Unit (ACU) has detected an internal fault related to its software or memory configuration. This typically indicates an EEPROM error where the controller fails a memory test upon power-up or is unable to exit its boot block program, leading to a malfunction in the armrest controls.

Applies to these machines

  • 7200R
  • 7215R
  • 7230R
  • 7260R
  • 7280R
  • 8235R
  • 8260R
  • 8285R
  • 8310R
  • 8310RT
  • 8335R
  • 8335RT
  • 8360R
  • 8360RT
  • 8230T
  • 8330T
  • 8430T
  • 9360R
  • 9410R
  • 9460R
  • 9460RT
  • 9510R
  • 9510RT
  • 9560R
  • 9560RT
  • 9330
  • 9430
  • 9530
  • 9630
  • 7760
  • 9560-9870 series
  • C-Series
  • T-Series
  • W-Series
  • 9560 STS
  • 9670 STS
  • T670
  • W660

Check the cause

  1. Perform a power cycle by turning the machine off, waiting a few moments, and restarting the engine to clear potential temporary software glitches

  2. Check battery voltage to ensure it is above 11.7V for 12V systems, as low voltage can cause unpredictable electronic module issues

Repair steps

  1. Update or reprogram software

    Reprogram the ACU with the latest software payload. This can be done via Over-the-Air (OTA) updates if the machine is equipped with an active JDLink subscription, or by a dealer using the Service ADVISOR diagnostic tool. The general process involves connecting the tool, clearing codes, reprogramming the controller, and then performing a full power cycle for 5 minutes.

  2. Replace Armrest Control Unit

    If reprogramming the ACU fails to resolve the issue and the fault code remains active, the Armrest Control Unit itself is likely faulty and will need to be replaced.

Parts you might need

(4)

Get help to fix this fault by requesting a quote

Browse other John Deere codes