John Deere 000630.11 – HCU: Dash Module Internal Issue During Boot Up
Issue description
The control unit has failed an internal self-test during the power-on or boot-up process. This indicates an issue with the Electrically Erasable Programmable Read-Only Memory (EEPROM), meaning that the system's calibration data is either missing or corrupt, or the EEPROM chip itself has malfunctioned. This is a Priority 3 fault, which means it should be checked but may not immediately stop machine operation.
Applies to these machines
18 machines- 9450
- 9550
- 9650
- 9660
- 9750
- 9760
- 9860
- 9560 STS
- 9660 STS
- 9760 STS
- 9860 STS
- 9660 CTS
- 9540 WTS
- 9560 WTS
- 9580 WTS
- 9640 WTS
- 9660 WTS
- 9680 WTS
Check the cause
Cycle power by turning the key switch OFF, waiting 30 seconds, and restarting the machine to see if it resolves a temporary boot-up glitch
Check the display for other diagnostic trouble codes; multiple CAN bus communication errors could indicate a broader electrical issue rather than a single faulty module
Visually inspect the wiring harnesses and connectors leading to the Header Control Unit and Cornerpost Control Unit for any signs of damage, corrosion, or loose connections
Repair steps
Prepare the machine
Attach the header to the combine and ensure the header wiring harness is securely connected. The machine should be on a level, firm surface.
Access diagnostic mode
Start the combine. On the cornerpost display or CommandCenter, press the diagnostic switch. 'DIA' or a similar indicator will appear.
Access calibration mode
Press the calibration switch. 'CAL' will appear on the display.
Select header calibration
Use the up/down arrow keys to navigate through the calibration menus until 'hdr' is displayed.
Enter header calibration mode
Press the enter switch to begin the header calibration process.
Follow on-screen prompts
The display will guide you through the calibration steps, which typically involve raising and lowering the header to establish its range of motion.
Save calibration
Once the calibration sequence is complete, save the settings as prompted.
Replace control unit
If the header calibration procedure fails or does not clear the fault code, the control unit itself is likely faulty and will require replacement.
Parts you might need
(2)Header Control Unit / Active Header Height Control Board
AH216995Alternative OEM Part Numbers: AH206125, AH220602, AH208046, AH213779, AH216994, AH217977. Casting Number: AH203857.
Alternative OEM Part Numbers: AH222503, AH221092, AH214602, AH204881.
Get help to fix this fault by requesting a quote