John Deere 630.13 – PL3: Calibration Fault / Not Calibrated
Issue description
Generated when the control software detects that a specific module or the transmission it controls has not completed its required calibration routine, or the calibration memory has been cleared, interrupted, or corrupted.
Applies to these machines
8 machines- 6110R
- 6120R
- 6130R
- 6145R
- 6155R
- 6175R
- 6195R
- 6215R
Check the cause
Determine if a calibration was recently aborted, or if the module software was recently updated/flashed (which automatically clears existing calibration values).
Look for other active diagnostic trouble codes (DTCs) related to speed sensors, clutch pedal potentiometers (e.g., PL3 524173.02), or supply voltage (e.g., PL3 000158.03/04) that will actively prevent a successful calibration.
Ensure the transmission hydraulic fluid is at the proper operating temperature (cold oil will cause calibration to fail or time out) and verify the transmission oil level is correct.
Repair steps
Warm Up
Run the tractor until the transmission fluid reaches normal operating temperature.
Prepare the Tractor
Park on a level surface, engage the park brake, ensure the transmission is in neutral, and turn off all implements/PTO.
Access Calibration Menu
Access the transmission calibration mode. This can usually be done through the tractor's CommandCenter display monitor or by connecting a laptop with John Deere Service Advisor.
Run Calibration
Initiate the Direct Drive transmission calibration. The system will prompt you to set the engine RPM to a specific speed.
Automated Process
Allow the automated calibration process to run. The PL3 module will cycle through the clutches and ranges to learn the fill volumes and engagement pressures. Do not touch the pedals or levers during this process.
Save Parameters
If the calibration completes successfully, cycle the key (turn the tractor off, wait a few minutes, and restart) to save the parameters to the module's memory. The 000630.13 code should change from 'Active' to 'Stored' and can then be cleared.
If Calibration Fails
If the tractor refuses to calibrate or drops out of calibration, hook up pressure gauges to the transmission test ports to verify that clutch and hydro pressures are within specification. A failure here usually points to a faulty control solenoid or speed sensor.
Parts you might need
(1)Transmission Control Solenoid Valve / Hydro Control Valve
RE578485Replaces older part number RE212709. Used to control hydraulic flow to the transmission clutches.
Get help to fix this fault by requesting a quote