000630.14
John Deere 000630.14: Module Clutch Calibration Values Are Out Of Range
Issue description
The Main Control Module (PTQ) has detected that the clutch calibration values are outside the acceptable range. This may affect the proper operation of the clutch system.
Check the cause
Main Control Module (PTQ) calibration values
Clutch system operation
Signal input to the Main Control Module (PTQ)
Repair steps
Verify
The calibration values stored in the Main Control Module (PTQ) using the appropriate diagnostic tool.
Reset
The calibration values if they are incorrect, following the manufacturer's procedure for recalibration.
Test
The clutch system operation after recalibration to ensure proper function.
Parts you might need
(0)Get help to fix this fault by requesting a quote