000639.13

John Deere 000639.13 – BCU, PLC, EPC, SIC: Vehicle CAN BUS Fault

Issue description

A control module has detected a high error rate in the messages it is receiving from the 29-bit Vehicle CAN (Controller Area Network) bus. This indicates a communication issue within the system rather than a failure of a specific component. The fault can be logged against various modules, including the Basic Control Unit (BCU), Park Lock Controller (PLC), Electronic PowrQuad Controller (EPC), or E-ICV and E-SCV Controller (SIC).

Applies to these machines

  • 6020
  • 6120
  • 6220
  • 6320
  • 6420
  • 6420S
  • 6520
  • 6620
  • 6820
  • 6920
  • 6920S
  • 6120L
  • 6220L
  • 6320L
  • 6420L
  • 6520L
  • 5620
  • 5720
  • 5820
  • 6100J
  • 6110J
  • 6125J
  • 6130J
  • 6145J
  • 6165J
  • 6180J
  • 6215
  • 6415
  • 6615
  • 6715
  • 7515

Check the cause

  1. Check for any other active or stored fault codes in all vehicle controllers, as this code is often secondary to another issue

  2. Inspect the physical layer of the CAN bus harness for signs of damage, chafing, corrosion, or loose connections

  3. Verify that the relevant controllers have a stable and clean power and ground supply

  4. With vehicle power off, measure the resistance between the CAN High (Yellow wire) and CAN Low (Green wire) circuits (should be approximately 60 Ohms; 120 Ohms indicates a missing terminating resistor or circuit break)

  5. Observe operating conditions to determine if the fault appears under specific scenarios, such as high vibration or rough terrain

Repair steps

  1. Address accompanying fault codes

    Diagnose and repair any other active fault codes first. Resolving the primary issue will often clear the 000639.13 informational code.

  2. Isolate the fault

    If no other codes are present but symptoms persist, disconnect other controllers from the CAN bus one at a time to see if the fault code disappears. This helps isolate a faulty controller or harness section.

  3. Repair harness and connectors

    If physical damage to the wiring or connectors is found, repair or replace the affected sections. Ensure all connector pins are clean, secure, and free of corrosion.

  4. Replace faulty controller

    If a specific controller is identified as the source of the excessive CAN bus errors (e.g., it is internally shorted or fails to communicate), replace the module.

Parts you might need

(6)
  • Fits various 5020, 6020, and J-series models

  • Basic Control Unit (BCU)

    AL206942

    Fits models such as 5100M, 5115M, 5080R

  • Basic Control Unit (BCU)

    AL150447

    Used in 6110, 6210, 6310, 6410, 6510 series tractors

  • Basic Control Unit (BCU)

    AL110259

    Used in 6110, 6210, 6310, 6410, 6510 series tractors

  • Cross-references to AL78924, AL110259, AL150447, AL179102 for 6010 series

  • Basic Control Unit (BCU)

    RE207317

    Verify fitment by serial number

Get help to fix this fault by requesting a quote