639

John Deere 639 – Multiple: CAN Bus Communication Fault

Issue description

The system has detected a fault within the Controller Area Network (CAN) bus, which is responsible for communication between electronic control units. This fault indicates that a controller has detected a loss of communication, an abnormal update rate, or a high error rate on the SAE J1939 data link. This disruption prevents ECUs (such as the Engine Control Unit, Transmission Control Unit, and others) from sharing necessary information, potentially leading to poor machine performance, failure of certain functions, or a complete machine shutdown.

Applies to these machines

  • 6020
  • 6120
  • 6220
  • 6230
  • 6320
  • 6420
  • 6420S
  • 6520
  • 6620
  • 6820
  • 6920
  • 6920S
  • 6x20
  • 6x30
  • 6R
  • 7x20
  • 7x30
  • 7R
  • 8x20
  • 8x30
  • 8R
  • 9230
  • 9330
  • 9430
  • 9530
  • 9630
  • 9x30
  • 9R

Check the cause

  1. Visually inspect the J1939 data link wiring harness for any signs of physical damage, chafing, pinching, or corrosion. Ensure connectors at major ECUs are secure and free of contamination.

  2. Check for stuck keys on the setup panel (SUP module), which can generate a related fault code (SUP 00524013.03) that mimics CAN bus issues.

  3. Disconnect any aftermarket electronic devices (e.g., ELDs, telematics) and re-test communication to rule out network interference.

  4. Perform a CAN bus resistance check: Turn ignition OFF, disconnect batteries, and measure resistance between Pin C (CAN High) and Pin D (CAN Low) at the 9-pin diagnostic connector. A healthy network should read approximately 60 Ω. A reading of 120 Ω indicates a missing terminating resistor or open circuit. A reading near 0 Ω indicates a short circuit between CAN High and CAN Low.

  5. Perform a CAN bus voltage check: Reconnect batteries, turn ignition ON, and measure voltage from Pin C (CAN High) to a known good ground (Pin A), which should be approximately 2.5V (typically 2.2V to 3.0V). Measure voltage from Pin D (CAN Low) to a known good ground (Pin A), which should also be approximately 2.5V (typically 2.0V to 2.3V).

Repair steps

  1. Address terminating resistor issues

    If the resistance reading was 120 Ω, a terminating resistor is missing or the circuit is open. Locate the two terminating resistors on the CAN bus backbone, unplug them, and measure their resistance directly (should be 120 Ω). Replace if open or incorrect.

  2. Isolate wiring or module shorts

    If the resistance reading was near 0 Ω or another incorrect value, begin unplugging controllers from the CAN bus one at a time. Re-check the resistance at the diagnostic port after each disconnection. When the resistance returns to a normal value (e.g., 120 Ω if one resistor is still connected), the last module disconnected or its harness section is likely the source of the fault.

  3. Correct voltage issues

    If voltage readings are incorrect (not ~2.5V), inspect the wiring harness for a short to power or ground, particularly in areas where the harness may have rubbed through and contacted the frame.

  4. Replace faulty components

    Replace any faulty terminating resistors with new OEM parts. If a specific controller is causing the fault, ensure its power and ground connections are clean and secure. If the problem persists, replace the controller.

  5. Clear codes and verify repair

    Reconnect the batteries, use a diagnostic tool or the machine's display to clear all fault codes, perform a key cycle, and let the engine idle for at least one minute to confirm the fault does not return. Road test if necessary.

Parts you might need

(3)

Get help to fix this fault by requesting a quote

Browse other John Deere codes