John Deere 000647.06 – ECU: Intercooler Hydraulic Fan Drive Solenoid High Amps
Issue description
The Engine Control Unit (ECU) has detected excessive electrical current (high amps) in the circuit for the intercooler hydraulic fan drive solenoid, a condition also described as low resistance in the engine fan drive circuit. This high current draw is typically caused by a short circuit to ground in the wiring harness or an internally shorted solenoid coil. When this fault is flagged, the system defaults the cooling fan to its maximum speed to prevent the engine from overheating.
Applies to these machines
7 machines- 6110M
- 6120M
- 6130M
- 5085E
- 5090E
- 5090EL
- 5100E
Check the cause
Visually inspect the wiring harness leading to the hydraulic fan drive solenoid for chafed or melted insulation, pinched wires, or corrosion. Pay close attention to the wiring leads on the solenoid coil itself.
Disconnect and inspect the solenoid's electrical connector for corrosion, moisture, or pushed-out pins. Clean the connector terminals and ensure a secure connection.
Measure the resistance across the solenoid coil terminals (expected range is typically 28 to 38 ohms) to check for an internal short.
With the solenoid and ECU disconnected, check the wiring harness for a short to ground by testing for continuity between each wire in the solenoid circuit and chassis ground.
With the key on and engine off, check for a short to power by testing for constant battery voltage on both wires at the solenoid connector.
Repair steps
Record and Clear Codes
Note any active and stored fault codes before beginning repairs.
Perform Visual and Resistance Checks
Follow the diagnostic steps outlined above.
Isolate the Fault
If the solenoid coil resistance is out of specification, the solenoid is the likely cause. If the solenoid tests good, the problem is likely in the wiring harness or, less commonly, the ECU itself.
Replace the Faulty Component
If the solenoid is faulty, replace it. If the wiring is damaged, repair or replace the affected section of the harness.
Final Verification
After the repair, clear all fault codes from the ECU. Start the tractor and operate it to ensure the fan functions correctly and the fault code does not return.
Parts you might need
(7)- Solenoid Valve AssemblyAL176895
Listed for 6110M, 6120M, and 6130M
Non Reversing Fan Speed Solenoid Hydraulic Valve
AT456398Complete valve assembly
- Solenoid Valve AssemblyRE286670
Fits models 6110M, 6120M, and 6130M
Fan Drive Solenoid Valve
AT455746Complete valve assembly
Fan Drive Solenoid Hydraulic Valve
4639168Complete valve assembly
Fan Drive Proportional Relief Solenoid Valve
AT468641Complete valve assembly
Hydraulic Fan Solenoid Valve Coil
F072153Solenoid coil only
Get help to fix this fault by requesting a quote