655
John Deere 655: Injector #5 Current Increase Exceeds Normal Rate
Issue description
The current supplied to Injector #5 is increasing at a rate that exceeds acceptable limits, which may affect engine performance or fuel delivery.
Check the cause
Injector #5 wiring and connections
Injector #5 electrical circuit integrity
Power supply to Injector #5
Repair steps
Inspect
Check the wiring and connections associated with Injector #5 for damage, corrosion, or loose contacts.
Test
Verify the electrical circuit for Injector #5 using a multimeter to ensure proper voltage and continuity.
Replace
If damage or malfunction is found, replace the affected wiring or Injector #5 as needed.
Parts you might need