871.04

John Deere 871.04 – ATC (Automatic Temperature Control): Refrigerant Pressure Sensor Circuit Voltage Low

Issue description

Triggered when the control unit detects a voltage of exactly 0 volts at the signal input for the refrigerant pressure sensor (B130, lead 2019), indicating a short to ground or open circuit. The controller restricts temperature control and de-activates the A/C compressor clutch to prevent damage, resulting in a loss of cabin cooling.

Applies to these machines

  • 6110R
  • 6120R
  • 6130R
  • 6145R
  • 6155R
  • 6175R
  • 6195R
  • 6215R
  • 6020 series
  • 6030 series
  • 7020 series
  • 8030 series
  • 9030 series
  • 6120-6420
  • 7720
  • 7820
  • 7920
  • 8230T
  • 8430
  • 9430
  • 9530
  • 9630
  • 6M series
  • 6R series
  • 7R series
  • 8R series
  • 9R series
  • S550
  • S650
  • S660
  • S670
  • S680
  • S690
  • S760
  • S770
  • S780
  • S790
  • T-Series
  • 444 Loader
  • 544 Loader
  • 644 Loader
  • 744 Loader
  • 844 Loader
  • 700 Dozer
  • 750 Dozer
  • 850 Dozer
  • Harvesters
  • Forwarders

Check the cause

  1. Inspect the wiring harness and connectors associated with the B130 refrigerant pressure sensor (specifically lead 2019) for broken wires, loose connections, or corroded terminals.

  2. Test electrical continuity in the sensor circuit using a multimeter to check for an open circuit (no continuity) or a short to ground (low resistance to ground).

  3. Measure the voltage at the sensor input connector with a multimeter to ensure proper supply voltage is reaching the sensor from the ATC module.

  4. Use a diagnostic tool to verify the operation of the B130 sensor itself to confirm if it has failed internally, assuming wiring and supply voltage are intact.

Repair steps

  1. Locate the Sensor

    Locate the B130 refrigerant pressure sensor on the high-side A/C line.

  2. Repair Wiring

    If the diagnostic checks revealed an open circuit or a short to ground in the harness (lead 2019), repair or replace the damaged wiring and ensure all connections are secure and properly insulated.

  3. Replace the Sensor

    If the wiring is good but the sensor is outputting 0 volts, the sensor is defective. Remove the faulty B130 sensor and install the replacement transducer using a new O-ring.

  4. System Reset

    Turn the tractor on and reset the system via the CommandCenter or diagnostic tool to clear the ATC 000871.04 fault code.

  5. Re-evaluation

    Start the engine and test the HVAC system comprehensively to ensure the A/C compressor clutch engages, the system regulates temperature effectively, and the code does not return.

Parts you might need

(2)
  • Refrigerant Pressure Sensor Transducer (Sensor B130)

    RE190340

    Monitors high-side A/C refrigerant pressure and provides electronic feedback to the ClimaTrak system. Features a 3-pin connector.

  • O-ring

    R10093

    Highly recommended to use a new O-ring for a complete and leak-free installation.

Get help to fix this fault by requesting a quote

Browse other John Deere codes