91.04

John Deere 91.04 – ECU, CAB, EPC, or OIC: Foot Throttle Sensor Circuit Voltage Problem

Issue description

The control unit measures a voltage below 0.3 volts at the signal input of the accelerator pedal potentiometer, indicating a short to ground, faulty sensor, poor wiring, or complete disconnection. This can lead to sluggish acceleration, poor throttle response, or the engine locking at idle.

Applies to these machines

  • 5065M
  • 5075M
  • 5085M
  • 5100M
  • 5100MH
  • 5100ML
  • 5115ML
  • 5095M
  • 5095MH
  • 5105M
  • 5015ML
  • 5E Series
  • 5M Series
  • 5045E
  • 5055E
  • 5065E
  • 6M Series
  • 6R Series
  • 6000 Series
  • 6230
  • 6330
  • 6430
  • 7000 Series
  • 7610
  • 7710
  • 7810
  • 7720
  • 7820
  • 7920
  • 8000 Series
  • 8130
  • 8230
  • 8330
  • 8430
  • 8530
  • 9000 Series
  • 9230
  • 9330
  • 9430
  • 9530
  • 9630
  • 204L
  • 304L
  • 244J
  • 444J
  • 544J
  • 624J
  • 644J
  • G-III Skidders

Check the cause

  1. Inspect the wiring harness associated with the accelerator pedal potentiometer for any signs of short circuits to ground, damaged insulation, rubbed-through areas, or exposed wires.

  2. Inspect all connectors and terminals in the foot throttle circuit. Ensure connections are secure and clean. Repair or replace any pins that are loose, pushed back, or corroded.

  3. Use a multimeter to test for ground faults in the wiring leading from the sensor to the control unit.

  4. Use a diagnostic tool or a multimeter to test the accelerator pedal potentiometer functionality. Verify it is providing accurate voltage readings (it should not drop below 0.3V).

Repair steps

  1. Prepare machine for service

    Turn off the machine, engage the parking brake, and disconnect the battery to prevent electrical surges while working with electronic components.

  2. Locate the sensor

    Locate the foot throttle sensor / accelerator pedal potentiometer, which is typically mounted directly to the accelerator pedal assembly under the operator platform or cab floor.

  3. Disconnect the harness

    Carefully unplug the wiring harness connector from the sensor.

  4. Remove the faulty sensor

    Unbolt the mounting hardware securing the potentiometer to the pedal linkage or floor bracket and remove the old unit.

  5. Install the new sensor

    Mount the direct-replacement sensor into position and secure it with the mounting hardware.

  6. Reconnect system

    Plug the wiring harness back into the new sensor, ensuring the connector clicks and locks into place. Reconnect the battery.

  7. Reset and test

    Turn the key on. Use the cab display or a diagnostic tool to clear the stored 000091.04 fault code. Start the engine and test the accelerator pedal response to ensure smooth operation and verify the code does not return. Note: Some machines may require a few minutes to relearn the new sensor's parameters.

Parts you might need

(6)
  • Sensor, with Cover

    SJ292682

    Fits 5E, 5M, and 6D series tractors

  • Foot Throttle Sensor

    RE261369

    Fits 8000 series tractors like the 8130, 8230, 8330, 8430

  • Foot Throttle Sensor

    AT456223

    Common on various construction/loader models

  • Rotary Foot Throttle Sensor

    LVA18799
  • Foot Throttle Sensor

    RE575333
  • Engine Speed Accelerator Pedal

    AT323306

    Complete pedal assembly

Get help to fix this fault by requesting a quote