926.03

John Deere 926.03 – SCO: Stepper Motor for E-SCV XIII, Supply Voltage Too High

Issue description

The system has detected that the supply voltage (BAT) for the stepper motor of Electronic Selective Control Valve 13 (E-SCV XIII) has risen above 16 volts. Excessive voltage can damage the internal components of the valve. As a protective measure, the control software will limit or completely disable the function of the affected selective control valve.

Applies to these machines

  • 6110R
  • 6120R
  • 6130R
  • 6145R
  • 6155R
  • 6175R
  • 6195R
  • 6215R
  • 6230R
  • 6250R
  • 6090M
  • 6100M
  • 6110M
  • 6120M
  • 6130M
  • 6145M
  • 6155M
  • 6175M
  • 6195M
  • 5090R
  • 5100R
  • 5115R
  • 5125R
  • 8R Series

Check the cause

  1. Monitor voltage at the stepper motor input to confirm if it is actively spiking above 16 volts

  2. Inspect the wiring harness and connections routing to the E-SCV XIII stepper motor for any signs of a short to power (chafed wires touching a higher voltage source)

  3. Verify that the power supply from the SCO module to the stepper motor is stable and within the required voltage range

  4. Inspect all electrical connectors at the valve and the SCO module for corrosion, looseness, or bent pins

Repair steps

  1. Disconnect Power

    Turn off the machine and disconnect the battery to prevent further electrical damage during repair.

  2. Repair Wiring

    If the diagnostic checks revealed a short to power in the harness, repair or replace the damaged section of the wiring.

  3. Clean Connections

    Clean and secure any loose or corroded electrical connections at the E-SCV XIII and the SCO module.

  4. Replace Faulty Power Supply/Module

    If the SCO module or voltage regulator is internally shorted and outputting excessive voltage to the valve, the module itself will need to be replaced.

  5. Replace the Stepper Motor

    If the high voltage condition has burnt out the stepper motor, or if the motor has an internal short causing the fault, remove the faulty E-SCV stepper motor and install a replacement.

  6. Recalibrate and Test

    Reconnect power, clear the fault codes, and cycle the SCV controls to ensure the voltage stays within the normal operating range and the valve functions properly.

Parts you might need

(5)
  • E-SCV Stepper Motor

    AL234434

    Current OEM Part Number

  • E-SCV Stepper Motor

    AL229568

    Superseded/Previous OEM Part Number

  • E-SCV Stepper Motor

    AL219124

    Superseded/Previous OEM Part Number

  • E-SCV Stepper Motor

    AL170550

    Superseded/Previous OEM Part Number

  • E-SCV Stepper Motor

    AL205608

    Superseded/Previous OEM Part Number

Get help to fix this fault by requesting a quote