John Deere 000096.04: Fuel Tank Level Sensor Signal Issue

Issue description

The Main Control Module (CCU) detects a low voltage signal from the Fuel Tank Level Sensor. This indicates a potential problem with the sensor's ability to provide an accurate fuel level reading.

Check the cause

  1. Fuel tank level sensor

  2. Wiring to the fuel tank level sensor

  3. Main Control Module (CCU)

Repair steps

  1. Inspect

    Inspect the Fuel Tank Level Sensor for damage or corrosion.

  2. Test

    Test the voltage output of the Fuel Tank Level Sensor using a multimeter.

  3. Check

    Check the wiring and connections between the Fuel Tank Level Sensor and the Main Control Module (CCU) for continuity and proper seating.