John Deere CAB1497 – Left Control Unit (E03): Unloading Auger Engage Warning
Issue description
The system has detected a warning related to the unloading auger engage function. Specifically, the Unloading Auger Engage driver has detected an open, short, over voltage, or over temperature condition. This indicates that the electronic signal from the control unit to the engagement mechanism is compromised. As a safety measure, the control unit will prevent the unloading auger from engaging until the fault is resolved.
Applies to these machines
25 machines- 9400
- 9410
- 9500
- 9501
- 9510
- 9600
- 9610
- 9540 WTS
- 9560 WTS
- 9580 WTS
- 9640 WTS
- 9660 WTS
- 9680 WTS
- 9560 STS
- 9660 STS
- 9670 STS
- 9760 STS
- 9770 STS
- 9860 STS
- 9870 STS
- S660
- S670
- S680
- S690
- CTS
Check the cause
Verify operational requirements are met (operator seated, road transport switch in 'field' position, multifunction handle not in neutral)
Check the combine's diagnostic display for any other active fault codes that could be related
Check system voltage at the battery and alternator to ensure they are within correct specifications, as an over-voltage condition can trigger this fault
Visually inspect the wiring harness and connectors leading to the unloading auger engagement mechanism and sensors (especially near the auger's pivot point) for damage, corrosion, or loose connections
Monitor voltage readings for the unloading auger sensors in the diagnostic menu for erratic or out-of-range values (e.g., spiking above 4.5V)
Repair steps
Isolate the faulty component
Based on the diagnostic checks, identify the likely cause. The fault's description points to an electrical issue (open, short, over voltage, or over temperature) in the auger engage driver circuit, which involves the Left Control Unit, wiring, and potentially a sensor or solenoid on the unloading auger system.
Test unloading auger position sensor
Test the sensor for correct voltage output and continuity. The ability to engage the auger depends on its swung-out position. If readings are erratic or incorrect, replace the sensor.
Inspect engagement solenoid
Locate the solenoid on the hydraulic valve block. Have an assistant operate the switch and check if the solenoid magnetizes (a screwdriver held near it should be pulled in). If it receives power but does not actuate, or receives no power, perform further electrical testing on the solenoid and its wiring.
Address wiring issues
Repair or replace any damaged sections of the wiring harness identified during inspection. Pay close attention to areas exposed to heat or chafing.
Replace faulty components
Replace any sensors or solenoids determined to be faulty with new OEM parts.
Perform calibration
Perform the Unloading Auger Swing Time Calibration through the diagnostic addresses on the cornerpost display (e.g., E03 100 and E03 101) to help the control unit relearn the swing time. Perform the Unloading Auger Engage Calibration if applicable to your model.
Clear codes and test
Clear the fault codes from the control unit's memory and test the unloading auger's operation. If the code persists, the Left Control Unit itself may require replacement.
Parts you might need
(3)Unloading Auger Sensor and Wiring Harness
AH145769OEM John Deere part. Monitors auger operation and connects to electrical interfaces.
OEM John Deere part. Detects position and angle of the unloading auger. Compatible with S-Series and STS models.
- Unloading Auger SensorAH142999
OEM John Deere part. Compatible with CTS and 9000 series models. Can substitute for AH128906, AH137183, AH140989, AH163979.
Get help to fix this fault by requesting a quote