Kubota 9 – Instrument Panel / Meter Panel / Display and Control Unit: Power Interruption Causing Clock Reset

Issue description

An interruption of the constant power supply required by the instrument panel or display unit has occurred, causing the clock to lose its setting and requiring it to be reset. This issue is likely related to the power supply or the clock circuit and is often accompanied by a clock warning light on the instrument panel.

Applies to these machines

  • KX018-4
  • KX101
  • U27-4
  • L2502
  • L3302HST
  • L6060HSTC
  • BX2370
  • BX2370-1

Check the cause

  1. Verify battery health and ensure that the terminals are clean and securely connected, as a loose or faulty connection is a frequent cause.

  2. Inspect the fuse associated with the instrument panel, often located in a fuse box near the battery.

  3. Perform a system reboot to clear temporary electronic faults by disconnecting the battery for approximately 10 minutes before reconnecting it.

Repair steps

  1. Turn on ignition

    Turn the starter switch or key to the 'RUN' or 'ON' position.

  2. Navigate to clock setting

    Use the display selector switches (often near the instrument panel) to navigate to the clock setting menu. Press the menu or selector button multiple times to cycle through options until the time display begins to blink.

  3. Adjust time

    Once in the setting mode, use the designated buttons to increase or decrease the hours and minutes to the correct time.

  4. Save setting

    Save the setting by pressing and holding one of the selector buttons until you hear a confirmation beep or the display stops blinking.

  5. Further diagnosis

    If the clock continues to reset after every power cycle, and the battery and fuses are confirmed to be in good condition, further investigation by a certified dealer may be necessary to inspect the control panel software and wiring.

Parts you might need

(10)
  • Discontinued

  • Instrument Panel (L3302HST)

    TC820-30210

    Panel assembly

  • Instrument Panel (BX2370)

    K2771-62502

    For S/N <=16880

  • Instrument Panel (BX2370)

    K2771-62510

    For S/N >=16881

  • Instrument Panel (BX2370-1)

    K2771-62502

    For S/N <=27773

  • Instrument Panel (BX2370-1)

    K2771-62510

    For S/N >=27774

  • Instrument Panel Glass (L3302HST)

    TC832-30230

    Glass only

  • Instrument Panel Glass (L2502)

    TC422-30230

    Glass panel board

  • Combination Switch (L2502)

    TC860-55120
  • Combination Switch (BX2370 / BX2370-1)

    K2581-62242