Kubota P1174 – Engine Control Module (ECM): EPR/CFV Voltage Supply High

Issue description

The supply voltage to the Electronic Pressure Regulator (EPR) or Continuous Flow Valve (CFV) exceeds 33.0 VDC for at least 5 seconds while the engine is running, which typically initiates a Power Derate 2 and turns on the Malfunction Indicator Lamp (MIL).

Applies to these machines

  • Kubota WG1605
  • Kubota WG1605-G-E3
  • Kubota WG1605-L-E3
  • Kubota WG1605-GL-E3
  • Kubota WG1903
  • Kubota WG2503
  • Kubota WG3800

Check the cause

  1. Check System Voltage: Test the alternator output and battery voltage. An overcharging alternator can cause high voltage spikes across the system.

  2. Inspect the Wiring Harness: Visually and physically inspect the wiring harness leading to the EPR/CFV. Look for damaged, chafed, or melted wires that could be causing a short to a higher voltage source.

  3. Test the EPR Power Circuit: Use a multimeter to back-probe the EPR connector and verify the actual voltage reaching the valve.

  4. Check ECM Grounds: Ensure the ECM grounds are clean, tight, and in their proper locations, as a bad ground can cause voltage irregularities.

Repair steps

  1. Disconnect Power

    Turn off the engine and disconnect the battery to prevent electrical shorts during repair.

  2. Repair Wiring

    If the diagnostic checks revealed a short to power or damaged wiring in the EPR circuit, repair or replace the affected section of the wiring harness.

  3. Address Charging System

    If the alternator was found to be overcharging (outputting > 33V on a 24V system, for example), replace the alternator or voltage regulator.

  4. Replace the EPR Valve

    If the wiring and charging system are functioning normally, the internal circuitry of the EPR valve itself has likely failed or shorted. Remove the fuel lines and electrical connector from the EPR, unbolt it from its mounting bracket, and install the new unit.

  5. Reassemble and Clear Codes

    Reconnect the battery, clear the DTCs from the ECM using a diagnostic scan tool, and run the engine to verify that the code does not return and the engine operates without derating.

Parts you might need

(5)
  • Electronic Pressure Regulator (EPR) / Continuous Flow Valve (CFV)

    EG523-46943

    Fits Kubota WG1605, WG1903, WG2503, and WG3800 propane/LPG/gaseous fuel systems.

  • Electronic Pressure Regulator (EPR) / Continuous Flow Valve (CFV)

    EG523-46920

    Fits Kubota WG1605, WG1903, WG2503, and WG3800 propane/LPG/gaseous fuel systems.

  • Electronic Pressure Regulator (EPR) / Continuous Flow Valve (CFV)

    23550-43330-71

    Fits Kubota WG1605, WG1903, WG2503, and WG3800 propane/LPG/gaseous fuel systems.

  • Electronic Pressure Regulator (EPR) / Continuous Flow Valve (CFV)

    E2033001B

    E-Controls Manufacturer Part Number

  • Electronic Pressure Regulator (EPR) / Continuous Flow Valve (CFV)

    2033001F

    E-Controls Manufacturer Part Number

Get help to fix this fault by requesting a quote

Browse other Kubota codes