P1716

Mahindra P1716 – EMS ECU: GNS Relay Plausible Error

Issue description

The Engine Management System (EMS) ECU has detected an implausible signal from the Gear Neutral Sensor (GNS) relay. The ECU receives an input indicating the relay contacts are 'sticky' (closed without a start request), providing a signal to the starter relay even when there is no request to start the engine. The GNS relay is part of the engine starting circuit and is designed to allow the starter motor to operate only when the transmission is in neutral or the clutch pedal is fully depressed.

Applies to these machines

  • Bolero Maxitruck Plus BS III (2013)

Check the cause

  1. Verify the primary symptom: the engine intermittently failing to start

  2. Ensure system voltage is between 8 and 16 volts with the ignition on (DTC detecting conditions)

  3. Visually inspect the GNS relay and its associated wiring for any visible signs of damage, corrosion, or loose connections

  4. Check for an open circuit in the GNS relay control wire

Repair steps

  1. Locate GNS relay

    Locate the GNS relay, which is typically found in the engine compartment fuse/relay box.

  2. Inspect wiring and connectors

    Inspect the wiring and connector for the GNS relay for integrity and proper connection.

  3. Test GNS relay

    If the wiring is intact, test the GNS relay by swapping it with a known good relay of the same type.

  4. Replace GNS relay

    If the relay is found to be faulty, it should be replaced.

  5. Diagnose EMS ECU

    If the relay and wiring are in good condition, the issue may lie within the EMS ECU, which controls the relay.