Mahindra P1731 – ECU: Error Sensor Supply 1

Issue description

The Engine Control Unit (ECU) has detected an error in the 'Sensor Supply 1' circuit, indicating an issue with the 5-volt power supply provided to various engine sensors. Specifically, this points to an unavailability of the 5V supply for the Accelerator Pedal Position (APP2) sensor and the Exhaust Gas Recirculation (EGR) valve. This condition is typically caused by a sensor short-circuiting to the battery or ground, or an open circuit in the wiring. When active, this fault causes the Check Engine (CHK ENG) lamp to blink on the instrument cluster.

Applies to these machines

  • Xylo mEagle CRDe

Check the cause

  1. Visually inspect the fitment and connection of the accelerator pedal module's wiring harness

  2. Inspect the fuse related to the metering unit to see if it has blown

  3. With the ignition switch OFF, disconnect the ECU connector and the pump metering unit connector. Use a multimeter to check for continuity between ECU connector pin K89 and metering unit connector pin 1

  4. Check for continuity between the metering unit fuse and metering unit connector pin 2

  5. Check the wiring harness for any short circuits to the ground

  6. Unplug sensors on the circuit one by one to isolate and identify if a specific faulty sensor is causing the voltage issue

Repair steps

  1. Secure connections

    Ensure the accelerator pedal module connector is properly and securely fitted. If it is loose, correct the connection, clear the fault code, and verify if the issue is resolved.

  2. Replace fuse

    If the metering unit fuse is found to be blown, replace it with a new one of the correct rating.

  3. Repair or replace wiring

    If the diagnostic checks reveal a lack of continuity or a short circuit in the wiring harness, the affected harness section must be replaced.

  4. Test and replace EGR valve

    Use a diagnostic tool to activate the EGR valve. If the valve does not respond or if the P1731 error repeats after clearing, replace the EGR valve.

  5. Replace faulty sensor

    If a specific sensor is identified as the cause of the short or open circuit during isolation testing, replace it. The Accelerator Pedal Sensor is a primary suspect for this fault code.

  6. Clear codes and verify

    After performing any repairs, clear the Diagnostic Trouble Code (DTC) using a diagnostic tool. Run the vehicle through a drive cycle (ignition OFF and ON) to ensure the fault does not reappear.

Parts you might need

(5)
  • Accelerator Pedal Sensor

    E007701981D91

    Generic/Mahindra Genuine. Associated with CRDe engine systems.

  • Accelerator Pedal Sensor

    E007701981D92

    Generic/Mahindra Genuine. Associated with CRDe engine systems.

  • EGR Valve

    Generic replacement

  • Wiring Harness

    Replacement is dependent on the specific vehicle model and harness section that is damaged

  • Metering Unit Fuse

    Refer to the vehicle's service manual or fuse box diagram for the correct amperage and type