A20000

Manitou A20000 – MP1: Strain Gauge Inconsistency

Issue description

The system has detected an inconsistency in the strain gauge readings, indicating a missing, out-of-range, or erratic signal. This points to a potential issue with the measurement or the component associated with the strain gauge. The fault affects the load moment indicator (LMI) system, which monitors boom load to prevent overloads. When triggered, it will typically display a warning and may lock out critical hydraulic functions, such as lifting or extending the boom, as a safety precaution.

Applies to these machines

  • MT932
  • MT1335
  • MT1435
  • MT1440
  • MT1637
  • MT1740
  • MT1840
  • MLT629
  • MLT634
  • MLT635
  • MLT732
  • MLT735
  • MLT-X 732
  • MT420
  • MT6xx
  • MT7xx
  • MT9xx

Check the cause

  1. Visually inspect the strain gauge sensor (typically bolted to the rear axle) for physical damage, rust, dirt, or moisture ingress.

  2. Inspect the full length of the sensor's cable for cuts, crushing, or abrasions.

  3. Check the electrical connectors for the strain gauge for corrosion, bent pins, or a loose connection.

  4. Check for continuity and for shorts to ground or power in the harness between the sensor and the MP1 controller.

Repair steps

  1. Clean sensor and mounting surface

    Remove the strain gauge sensor from the axle. Thoroughly clean both the mounting surface on the axle and the contact surface of the sensor to ensure a clean, flat connection. Re-install the sensor securely. It is recommended to use Loctite on the mounting hardware and RTV silicone sealant around the edges to prevent future moisture ingress.

  2. Prepare for recalibration

    Ensure the machine is on flat, level ground with correct tire pressures, wheels straight, and parking brake engaged. Fully retract and lower the boom. Have a suitable test load ready.

  3. Enter calibration mode

    For MT models: Press the 'parachute' (hydraulic cut-out override) button once, then within 10 seconds press and hold both the 'suspended load' and 'test' buttons simultaneously until the calibration screen appears. For MLT-X models: Press the 'bucket' and 'test' buttons simultaneously until the system beeps twice.

  4. Perform angle and load sensor calibration

    Follow on-screen prompts, pressing 'test' to confirm each step: 1) With boom fully lowered/retracted, press 'test'. 2) Raise boom to max height (fully vertical) while fully retracted, press 'test'. 3) Increase engine to max revs. 4) Lower boom as fast as possible to lowest position, press 'test'. 5) Confirm boom is fully down/retracted, press 'test'. 6) Attach forks/attachment. 7) Hold 'parachute' button and pick up test load just off the ground. 8) Extend boom until rear wheels just begin to lift off the ground. 9) Wait 5 seconds to stabilize, then press 'test' to set calibration. Retract boom and test LMI operation.

  5. Replace strain gauge sensor

    If cleaning and recalibration fail to clear the fault, the strain gauge sensor is likely faulty. Replace the sensor and perform the full recalibration procedure again.

Parts you might need

(2)
  • Strain Gauge / Load Security Sensor

    241976

    Bolted on the axle, fits a wide range of MT and MLT models. Verify fitment by serial number.

  • Strain Gauge52506420

    Verify fitment by serial number.

Get help to fix this fault by requesting a quote

Browse other Manitou codes