Massey Ferguson 0.0.43 – Dash (Instrument Cluster): Service Counter Issue
Issue description
Fault or synchronization error regarding the machine's internal maintenance/service interval counter.
Applies to these machines
6 machines- 5710SL
- 5711SL
- 5712SL
- 5713SL
- T4
- T4 (2017-2023)
Check the cause
Verify the current service interval status on the dash display
Attempt a factory default reset or service counter reset via the dash menu
Repair steps
Reset service counter
Attempt a standard service counter reset or factory default reset via the dash menu.
Connect diagnostic software
If a standard service counter reset does not clear the code, connect dealer-level diagnostic software such as the AGCO Electronic Diagnostic Tool.
Re-flash or replace dash module
Use the diagnostic software to re-flash the dash module. If the internal memory for the service counter has failed and cannot be reset or re-flashed, replace the dash panel.
Parts you might need
(1)Dash Panel / Instrument Cluster
Required if the internal memory for the service counter has failed and cannot be reset.
Get help to fix this fault by requesting a quote