Massey Ferguson 00.00.5F – Dash: Issue With Voltage From Navigation Buttons (Dash)
Issue description
The system has detected an abnormal electrical signal (voltage out of range, missing, or shorted) coming from the navigation buttons, which are the rocker switches used to navigate the menus of the central liquid crystal display on the instrument panel.
Applies to these machines
21 machines- 7714
- 7715
- 7715S
- 7716
- 7716S
- 7718
- 7718S
- 7719
- 7720
- 7720S
- 7722
- 7722S
- 7724
- 7724S
- 7726
- 7726S
- Tier 4 (2015-2021)
- 5710SL
- 5711SL
- 5712SL
- 5713SL
Check the cause
Test System Voltage: Use a multimeter to check the battery voltage. A fully charged battery should read around 12.6V when off, and between 13.5V and 14.5V with the engine running. Low system voltage or a failing alternator can trigger erroneous dash codes.
Inspect Wiring and Harnesses: Check the wiring harnesses connecting the navigation buttons to the dash for rub points, open circuits, or shorts to ground.
Check Connections: Inspect the terminals and connectors at the dash and the buttons for dirt, moisture, or corrosion.
Verify Grounds: Check the ground connections for the dashboard, as a bad ground is a frequent cause of voltage-related faults.
Repair steps
Disconnect battery
Disconnect the battery before working on the tractor's electrical system to prevent accidental shorts.
Access wiring
Access the rear of the instrument panel/console to reach the navigation button wiring.
Clean terminals
Clean any corroded terminals or connectors using a wire brush and a baking soda solution to ensure a solid electrical connection.
Repair wiring
Repair or replace any damaged wiring harnesses found during the visual inspection.
Replace navigation button assembly
If the wiring, grounds, and system voltage are all verified as good, the fault is likely an internal failure of the navigation button switches or the dash module itself. Replace the faulty navigation button assembly.
Verify repair
Reconnect the battery, turn the ignition key on, and verify if the fault code clears and the central display menus can be navigated successfully.
Parts you might need
(3)Massey Ferguson Central Display Navigation Buttons / Switch Assembly
Generic
Massey Ferguson Instrument Panel / Dash Assembly
Generic
Massey Ferguson Heavy-Duty 12V Battery
If the battery fails load testing and is causing low voltage
Get help to fix this fault by requesting a quote