Massey Ferguson 04.00.05 – TRANS: Transmission High Pressure Sensor 2 Signal Voltage Issue
Issue description
This code indicates that the electronic control system has detected an abnormal signal voltage from Transmission High Pressure Sensor 2. The fault typically points to an 8.5 V supply error, an open circuit, or a short in the sensor's signal circuit.
Applies to these machines
43 machines- 7714
- 7715
- 7715S
- 7716
- 7716S
- 7718
- 7718S
- 7719
- 7720
- 7720S
- 7722
- 7722S
- 7724
- 7724S
- 7726
- 7726S
- Tier 4 (2015-2021)
- 4707
- 4708
- 4709
- 4710
- 5608
- 5609
- 5610
- 5611
- 5612
- 5613
- 5710SL
- 5711SL
- 5712SL
- 5713SL
- 7614
- 7615
- 7616
- 7618
- 7619
- 7620
- 7622
- 7624
- 7626
- 8650
- 8670
- 8690
Check the cause
Verify that the sensor is receiving the correct 8.5 V reference voltage
Inspect the wiring harness between the Transmission Control Module and the X34 sensor for chafed wires, corrosion in the connector pins, or signs of a short-to-ground/short-to-power
Ensure the connector is firmly seated and free of moisture or hydraulic fluid ingress
Repair steps
Park and secure the tractor
Park the tractor on a level surface, turn off the engine, and engage the hand brake or ParkLock.
Relieve system pressure
Relieve any residual pressure in the transmission/hydraulic system according to standard safety procedures.
Locate the sensor
Locate Transmission High Pressure Sensor 2 (X34) on the transmission housing.
Disconnect the sensor
Disconnect the electrical connector from the sensor.
Remove the sensor
Unscrew and remove the faulty sensor.
Install the new sensor
Install the new sensor and tighten to the manufacturer's specified torque. Reconnect the electrical harness.
Perform transmission calibration
A transmission calibration procedure MUST be carried out systematically after changing the transmission high pressure sensor. Preliminary conditions for calibration: Hand brake applied or ParkLock engaged; Power Control lever in the neutral position; High/low speed range (Hare/Tortoise) in neutral (symbols should flash alternately on the right-hand screen).
Clear fault code and test
Clear the 04.00.05 fault code using a diagnostic tool and test drive the tractor to ensure the code does not return.
Parts you might need
(2)Transmission High Pressure Sensor (Sensor 2 / X34)
4368842M1Verify exact part number against tractor's serial number/VIN via AGCO parts catalog before ordering.
Transmission High Pressure Sensor (Sensor 2 / X34)
ACP0426120Alternate part number. Verify exact part number against tractor's serial number/VIN via AGCO parts catalog before ordering.
Get help to fix this fault by requesting a quote