Massey Ferguson 06.03.19 – TRANS1: Issue With Signal From PTO 1000 ECO Button Dyna VT (TRANS1)
Issue description
This code indicates that the transmission control unit is receiving an irregular, missing, or implausible electrical signal from the button used to engage the 1000 ECO PTO speed. This is typically caused by a mechanical failure inside the switch (such as the button sticking or being held down for too long), an open circuit, or a short circuit in the wiring harness connecting the switch to the controller.
Applies to these machines
17 machines- 7720S
- 7724S
- 7716
- 7720
- Tier 4 (2015-2021)
- 7718
- 7722
- 7722S
- 7715S
- 7718S
- 7715
- 7726
- 7719
- 7714
- 7724
- 7716S
- 7726S
Check the cause
Check the PTO 1000 ECO button on the armrest/side console for physical damage, sticking, or debris that might be holding the button down.
Remove the switch and use a multimeter to test for proper continuity when the button is pressed and released. A switch that reads closed continuously has failed mechanically.
Inspect the wiring harness and connectors between the PTO switch and the TRANS1 controller. Look for signs of chafing, corrosion, or loose pins that could cause an open or short circuit.
Look for accompanying voltage or CAN BUS fault codes (e.g., 06.03.1B for ECO Speed Solenoid voltage issues or 06.01.A1 for CAN BUS message issues) which might indicate a broader harness or module issue rather than just a faulty switch.
Repair steps
Disconnect Power
Disconnect the tractor's battery to ensure safety and prevent electrical shorts during the repair.
Access the Switch
Carefully pry up or remove the trim/console panel on the right-hand armrest that houses the PTO control switches.
Disconnect Harness
Unplug the electrical connector from the back of the faulty PTO 1000 ECO switch.
Remove the Switch
Depress the retaining clips on the sides of the switch body and push it up and out of the console panel.
Install New Part
Insert the new replacement PTO switch into the panel until the retaining clips click securely into place.
Reconnect
Plug the electrical harness back into the new switch and reinstall the console panel.
Clear Codes
Reconnect the battery, turn the ignition on, and use a diagnostic service tool or the tractor's instrument panel display to clear the stored 06.03.19 fault code.
Test Operation
Start the tractor and test the PTO 1000 ECO function to verify the signal is being read correctly and the PTO engages/disengages as commanded.
Parts you might need
(9)PTO Control Switch / Rocker Switch
4355770M3Primary OEM part. Supersedes older revisions 4355770M2 and 4355770M1. Standard fitment across multiple Massey Ferguson ranges including the 5600, 5700, 6600, 6700, 7600, 7700, and 8700 series.
PTO Control Switch / Rocker Switch
4355770M2Older revision superseded by 4355770M3.
PTO Control Switch / Rocker Switch
4355770M1Older revision superseded by 4355770M3.
PTO Control Switch / Rocker Switch
4296050M1Related PTO switch OEM number for this console.
PTO Control Switch / Rocker Switch
4351040M2Related PTO switch OEM number for this console.
PTO Control Switch / Rocker Switch
S.170367Sparex aftermarket alternative.
PTO Control Switch / Rocker Switch
56755Bepco/Alternative aftermarket.
PTO Control Switch / Rocker Switch
50701002Aftermarket alternative.
PTO Control Switch / Rocker Switch
B58124Aftermarket alternative.
Get help to fix this fault by requesting a quote