Massey Ferguson 0A.23.22 – Transmission/Hydraulic Control Unit or Mid Mount Valve Module / EHR module: External Hydraulic Valve 2 Issue
Issue description
Malfunction in the second electronic hydraulic remote (EHR) valve circuit. The underlying condition is typically an electrical connection problem on the hydraulic valve, a faulty spool position sensor value, or a mechanical sticking of the spool valve that prevents it from responding correctly to the control module's commands.
Applies to these machines
41 machines- 7724S
- 5712SL
- 7722
- 7722S
- 5713SL
- 7720S
- 7716
- 7718
- T4
- 7715
- 5710SL
- 7726
- 7726S
- 5711SL
- 7718S
- 7719
- 7714
- 7716S
- 7720
- Tier 4 (2015-2021)
- 7715S
- 7724
- 4707
- 4708
- 4709
- 4710
- 5608
- 5609
- 5610
- 5611
- 5612
- 5613
- 7614
- 7615
- 7616
- 7618
- 7619
- 7620
- 7622
- 7624
- 7626
Check the cause
Inspect the hydraulic oil for contamination (dirt or metal shavings) and check for a blocked hydraulic or transmission filter
Check the hydraulic couplers and hoses on Valve 2 for physical damage, blockages, or restrictions
Inspect the wiring harness and electrical connector at External Hydraulic Valve 2 for corrosion, loose pins, or broken wires
Test the spool position sensor and the solenoid coil on Valve 2 for proper resistance and voltage to determine if the issue is electrical (failed solenoid/sensor) or mechanical (stuck spool)
Repair steps
Safety & Prep
Lower all implements to the ground. Turn off the engine and cycle the remote levers/buttons to relieve all hydraulic pressure in the system.
Locate the Valve
Access the external hydraulic valve block (usually located at the rear of the tractor above the rear axle). Identify the section corresponding to Valve 2.
Disconnect Electricals
Unplug the electrical connectors from the solenoid coil and the spool position sensor on Valve 2.
Remove the Valve/Solenoid
If replacing the solenoid/sensor: Unbolt the faulty solenoid coil or sensor from the valve body. If replacing the entire valve section: Disconnect the hydraulic lines attached to Valve 2. Unbolt the tie-rods holding the valve stack together and carefully remove the Valve 2 section.
Installation
Install the new valve section, solenoid, or sensor. Ensure all O-rings are seated correctly. Torque all bolts to OEM specifications.
Reassembly
Reconnect the hydraulic lines and plug in the electrical connectors.
Testing & Clearing
Top up the hydraulic fluid if any was lost. Start the tractor and operate the remote to bleed air from the system. Check for leaks. Finally, use a compatible diagnostic tool to clear the 0A.23.22 DTC from the system.
Parts you might need
(6)External Hydraulic Valve Assembly / Spool Valve Block
1026699M92Generic OEM reference for older single spool conversions
External Hydraulic Valve Assembly / Spool Valve Block
TS3200MGeneric OEM reference for older single spool conversions
Solenoid Coil for Hydraulic Valve
Commonly used on 54/64/74/76 series EHR valves
Spool Position Sensor
Specific to the EHR valve block
Hydraulic Oil Filter / Transmission Filter
Model specific, highly recommended to replace during this service
Hydraulic Couplers
8250-4female body half, 1/2" NPT, if the coupler itself is damaged
Get help to fix this fault by requesting a quote