Massey Ferguson 0A.5X.13 – Implement/Hydraulic Control Unit: External Hydraulic Valve 5 Issue
Issue description
The onboard diagnostic system has detected a malfunction in the 5th external hydraulic remote valve (spool valve). The underlying condition is typically an electrical fault (such as an open circuit, short to ground, or short to power in the solenoid circuit), a communication error with the valve's pilot pressure control, or a mechanical blockage causing the valve to stick.
Applies to these machines
41 machines- 7724S
- 5712SL
- 7722
- 7722S
- 5713SL
- 7720S
- 7716
- 7718
- T4
- 7715
- 5710SL
- 7726
- 7726S
- 5711SL
- 7718S
- 7719
- 7714
- 7716S
- 7720
- Tier 4 (2015-2021)
- 7715S
- 7724
- 4707
- 4708
- 4709
- 4710
- 5608
- 5609
- 5610
- 5611
- 5612
- 5613
- 7614
- 7615
- 7616
- 7618
- 7619
- 7620
- 7622
- 7624
- 7626
Check the cause
Check the wiring harness and connectors leading to the #5 external hydraulic valve solenoid for rub points, corrosion, or disconnected pins
Use a multimeter to check for open circuits, shorts to ground, or shorts to power on the solenoid circuit, and measure the solenoid coil resistance
Verify if the valve is mechanically stuck, as the system may block all valves as a safety precaution when this code is thrown
Verify that the system is receiving adequate hydraulic pressure and that the hydraulic fluid level and filters are in good condition
Repair steps
Clear and Reset
If the valves have been electronically blocked by the control unit due to the fault, first attempt to delete the error code from the dashboard control unit to unlock the valves. Test operation to see if the code returns.
Repair Wiring
If the diagnostic checks revealed damaged wiring or a corroded connector at the #5 valve, repair the harness or replace the pigtail connector.
Replace Solenoid/Coil
If the wiring is intact but the solenoid coil fails the resistance test, replace the solenoid coil on the #5 valve.
Replace the Spool Slice
If the valve is internally damaged, leaking, or the integrated electronics have failed, the entire electric spool slice must be replaced.
Programming
Note that if a new electric spool slice is installed on modern series, the new unit will need to be programmed/calibrated to the tractor's control unit using a dealer diagnostic tool.
Parts you might need
(6)Electric Spool Slice (Valve Assembly)
3797234M6Supersedes 3797234M5, 3797234M4, 3797234M3, 3796930M12. Used on modern electronic remote setups; requires programming to the tractor after installation.
Pilot Pressure Control for Electric Spool Valve
R917008801Manual Spool Valve
3597161M93Only applicable if the machine uses mechanical linkages rather than electronic solenoids.
Manual Spool Valve
3904737M1Only applicable if the machine uses mechanical linkages rather than electronic solenoids.
Manual Spool Valve
3904736M1Only applicable if the machine uses mechanical linkages rather than electronic solenoids.
Manual Spool Valve
1860100M95Only applicable if the machine uses mechanical linkages rather than electronic solenoids.
Get help to fix this fault by requesting a quote