Massey Ferguson 0A.73.13 – Onboard diagnostic system: External Hydraulic Valve 7 Issue
Issue description
A malfunction, often electrical or a connection problem, associated with the 7th external hydraulic remote/spool valve on the tractor's hydraulic manifold. The system detects that the valve is not responding correctly to command signals.
Applies to these machines
41 machines- 7724S
- 5712SL
- 7722
- 7722S
- 5713SL
- 7720S
- 7716
- 7718
- T4
- 7715
- 5710SL
- 7726
- 7726S
- 5711SL
- 7718S
- 7719
- 7714
- 7716S
- 7720
- Tier 4 (2015-2021)
- 7715S
- 7724
- 4707
- 4708
- 4709
- 4710
- 5608
- 5609
- 5610
- 5611
- 5612
- 5613
- 7614
- 7615
- 7616
- 7618
- 7619
- 7620
- 7622
- 7624
- 7626
Check the cause
Visual & Electrical Inspection: Inspect the wiring harness leading to External Hydraulic Valve 7 for frayed wires, corrosion in the connector pins, or loose connections.
Solenoid Testing: Use a multimeter to check the resistance of the solenoid on Valve 7 and compare it to a known working valve (e.g., Valve 1 or 2) to determine if the coil has failed.
Hydraulic Fluid Check: Verify that the hydraulic fluid is at the correct level and free of debris, which could cause the spool valve to stick.
Code Clearing: Attempt to clear the DTC using a compatible Massey Ferguson diagnostic tool to see if the code is an active hard fault or a stored historical error.
Repair steps
Depressurize the System
Turn off the tractor and cycle the hydraulic controls to relieve any residual pressure in the external hydraulic system.
Locate Valve 7
Identify External Hydraulic Valve 7 on the rear hydraulic manifold block.
Disconnect Electricals
Carefully unplug the electrical connector from the valve's solenoid.
Remove the Valve
Unbolt the retaining bolts holding the spool valve to the hydraulic block. Have a catch pan ready, as some hydraulic fluid will leak out.
Inspect/Replace
If the issue is a failed O-ring or a stuck spool, you may be able to clean and reseal it. If the solenoid or internal valve body is faulty, replace the entire valve assembly.
Reinstall
Install the new valve with new O-rings. Torque the mounting bolts to the OEM specifications.
Reconnect and Test
Plug the electrical connector back in. Start the tractor, top up the hydraulic fluid if necessary, and test the operation of the 7th remote.
Clear Codes
Use a diagnostic tool to clear code 0A.73.13 from the system.
Parts you might need
(4)External Hydraulic Spool Valve / Solenoid Assembly
1032485M91Generic OEM Part Number; verify fitment for specific Tier 4 model
External Hydraulic Spool Valve / Solenoid Assembly
1026699M92Generic OEM Part Number; verify fitment for specific Tier 4 model
Hydraulic Manifold O-Rings
195561M1Standard MF hydraulic pipe/cover seals; verify exact size for the modern manifold block
Hydraulic Couplers
If the physical remote outlets are damaged, e.g., 1/2" NPT female body halves
Get help to fix this fault by requesting a quote