Massey Ferguson 0B.02.14 – Mid Mount Valve Module: Loader Mid Mount Electro Valve Solenoid Low Amp Draw
Issue description
The control module is detecting less electrical current than expected when it commands the solenoid to turn on. This typically indicates high electrical resistance in the circuit, a failing solenoid coil (internal break or increased resistance), a poor ground connection, or a damaged wire/corroded connector.
Applies to these machines
40 machines- 5710SL
- 5711SL
- 5712SL
- 5713SL
- T4
- 4707
- 4708
- 4709
- 4710
- 5608
- 5609
- 5610
- 5611
- 5612
- 5613
- 7614
- 7615
- 7616
- 7618
- 7619
- 7620
- 7622
- 7624
- 7626
- 7714
- 7715
- 7715S
- 7716
- 7716S
- 7718
- 7718S
- 7719
- 7720
- 7720S
- 7722
- 7722S
- 7724
- 7724S
- 7726
- 7726S
Check the cause
Inspect the wiring harness and connectors between the Mid Mount Valve Module and the Loader Mid Mount Electro Valve Solenoid for corrosion, loose pins, or physical damage
Disconnect the affected solenoid and measure the resistance of the solenoid coil using a multimeter. Compare the reading against OEM specifications. An unusually high resistance reading or an 'OL' (open loop) confirms the solenoid coil has failed internally
Check the ground circuit for the solenoid to ensure it is clean and tight, as a poor ground will cause a low amp draw
Check for proper voltage at the solenoid connector when the loader function is commanded on from the cab
Repair steps
Power Down
Turn off the tractor and disconnect the negative battery cable to prevent electrical shorts.
Locate the Valve
Locate the Mid Mount Electro Valve block (typically mounted on the right side of the tractor chassis, under the cab, or near the loader mast connections).
Disconnect Wiring
Unplug the electrical connector from the specific solenoid throwing the code.
Remove the Coil
Remove the retaining nut or clip at the end of the valve stem that holds the solenoid coil in place.
Swap the Coil
Slide the old solenoid coil off the valve cartridge stem. Slide the new OEM replacement coil onto the stem.
Reassemble
Reinstall and tighten the retaining nut/clip. Reconnect the electrical connector securely.
Test
Reconnect the battery. Turn the key on, clear the stored DTCs using a compatible diagnostic tool, and test the loader functions to ensure the code does not return.
Parts you might need
(5)Loader Mid Mount Electro Valve Solenoid / Hydraulic Valve Solenoid
3794719M2Common on 5400, 5600, 5700, 6200 series
Loader Mid Mount Electro Valve Solenoid / Hydraulic Valve Solenoid
3904281M2Loader Mid Mount Electro Valve Solenoid / Hydraulic Valve Solenoid
3909720M91Loader Mid Mount Electro Valve Solenoid / Hydraulic Valve Solenoid
7302601101Common on 5400, 6400, 6600 series
Loader Mid Mount Electro Valve Solenoid / Hydraulic Valve Solenoid
3619762M1
Get help to fix this fault by requesting a quote