10.00.30

Massey Ferguson 10.00.30 – AIRCON: Issue With Signal To Right Cab Fan Speed Controller (AIRCON)

Issue description

The climate control system has detected an electrical fault (such as an open circuit, short circuit, or component failure) in the signal circuit communicating with the right-side blower motor resistor/speed regulator. When this occurs, the right cab fan may only operate on a single speed (usually high) or fail to operate entirely.

Applies to these machines

  • 7724S
  • 5712SL
  • 7722
  • 7722S
  • 5713SL
  • 7720S
  • 7716
  • 7718
  • T4
  • 7715
  • 5710SL
  • 7726
  • 7726S
  • 5711SL
  • 7718S
  • 7719
  • 7714
  • 7716S
  • 7720
  • Tier 4 (2015-2021)
  • 7715S
  • 7724
  • 4707
  • 4708
  • 4709
  • 4710
  • 5410 through 5480
  • 5608
  • 5609
  • 5610
  • 5611
  • 5612
  • 5613
  • 5709S/SL through 5713S/SL
  • 6445 through 6499
  • 6612 through 6616
  • 7614
  • 7615
  • 7616
  • 7618
  • 7619
  • 7620
  • 7622
  • 7624
  • 7626
  • 7714 through 7726 (including S models)
  • 3600 Series
  • 4200 Series
  • 4300 Series
  • 4400 Series
  • 6200 Series
  • 7400 Series
  • 8200 Series
  • 8400 Series

Check the cause

  1. Verify the symptom by turning on the tractor's AC/heater and testing the right-side cab fan on all manual speed settings. If it only works on high or not at all, the resistor is likely faulty.

  2. Access the right cab fan speed controller (resistor) and inspect the wiring harness and connector for melted plastic, corrosion, or loose pins.

  3. Test the right blower motor for excessive amperage draw or physical binding. A failing blower motor drawing too much current will quickly burn out a new replacement resistor.

Repair steps

  1. Turn off the tractor ignition and disconnect the battery to prevent electrical shorts.

    Turn off the tractor ignition and disconnect the battery to prevent electrical shorts.

  2. Access the HVAC blower assembly.

    On most of the listed Massey Ferguson models, this requires removing the inner cab roof liner or the exterior roof hatch, depending on the specific cab configuration.

  3. Locate the right cab fan speed controller (blower motor resistor).

    It is mounted directly into the HVAC ducting/housing near the right blower motor to allow airflow to cool it.

  4. Disconnect the electrical wiring harness from the resistor.

    Disconnect the electrical wiring harness from the resistor.

  5. Remove the retaining screws holding the resistor in place and pull the old unit out of the housing.

    Remove the retaining screws holding the resistor in place and pull the old unit out of the housing.

  6. Insert the new blower motor resistor into the housing and secure it with the screws.

    Insert the new blower motor resistor into the housing and secure it with the screws.

  7. Reconnect the electrical harness.

    If the old plug was melted, splice in a new pigtail connector.

  8. Reassemble the cab roof/HVAC access panels.

    Reassemble the cab roof/HVAC access panels.

  9. Reconnect the battery, start the tractor, and test the fan on all speed settings.

    Clear the 10.00.30 fault code from the AIRCON module.

Parts you might need

(6)
  • Blower Motor Resistor (OEM AGCO)

    3304510M92

    Most current/common

  • Blower Motor Resistor (OEM AGCO)

    3304510M91
  • Blower Motor Resistor (OEM AGCO)

    3902326M91
  • Blower Motor Resistor (OEM AGCO)

    3904295M2
  • Blower Motor Resistor (OEM AGCO)

    V37222400
  • Blower Motor Resistor (Sparex)

    S.129812

    Aftermarket Option

Get help to fix this fault by requesting a quote