Massey Ferguson 10.01.20 – Air Conditioning Module (AIRCON): Issue With Air Circulation Flap Motors (AIRCON)
Issue description
Malfunction in the actuator motor responsible for opening and closing the air recirculation flap within the cab's HVAC system, preventing the system from properly regulating fresh versus recirculated air.
Applies to these machines
41 machines- 7724S
- 5712SL
- 7722
- 7722S
- 5713SL
- 7720S
- 7716
- 7718
- T4
- 7715
- 5710SL
- 7726
- 7726S
- 5711SL
- 7718S
- 7719
- 7714
- 7716S
- 7720
- Tier 4 (2015-2021)
- 7715S
- 7724
- 4707
- 4708
- 4709
- 4710
- 5608
- 5609
- 5610
- 5611
- 5612
- 5613
- 7614
- 7615
- 7616
- 7618
- 7619
- 7620
- 7622
- 7624
- 7626
Check the cause
Wiring and Voltage Check: Use a multi-meter to verify that proper voltage is reaching the flap motor actuator. Inspect the machine's wiring harness for any damage, breaks, or pinched wires leading to the HVAC unit.
Connection Inspection: Check the electrical connectors at the flap motor and the AIRCON module for corrosion, rust, or bad contacts. Clean or repair them if necessary.
Panel and Sensor Verification: Ensure the issue is not originating from the control panel. Related codes (such as 10.00.16 for the temperature dial, 10.00.17 for the fan speed dial, or 10.00.18 for the cab temperature sensor) can sometimes cause the AIRCON module to send incorrect signals to the flap motors.
Mechanical Binding: Manually inspect the air circulation flap to ensure it is not physically jammed by dirt, debris, or a broken linkage, which would cause the motor to over-amp and throw a fault.
Repair steps
Power Down
Turn off the tractor and disconnect the battery to prevent electrical shorts.
Access the HVAC Unit
Remove the necessary cab interior trim panels (often located in the cab roof or under the seat, depending on the specific tractor series) to gain access to the HVAC housing.
Locate the Actuator
Identify the air circulation flap motor (actuator) mounted on the side of the HVAC air distribution box.
Disconnect
Unplug the electrical wiring harness connector from the faulty flap motor.
Remove the Motor
Remove the mounting screws securing the actuator to the housing. Carefully pull the motor away, noting the position of the mechanical linkage/spline.
Install the New Part
Align the new actuator's linkage with the air circulation flap door. Secure it with the mounting screws.
Reconnect and Test
Plug the wiring harness back in. Reconnect the battery, turn on the ignition, and operate the HVAC controls (switching between fresh air and recirculation) to verify the flap opens and closes smoothly without binding.
Reassemble
Reinstall all cab trim panels.
Parts you might need
(4)Heater Actuator / Flap Motor
ACW0932930Common replacement for cab climate control actuators
AGCO Actuator Assembly
ACP0738080Actuator Assembly
764805M92Air Circulation Flap Motor / HVAC Blend Door Actuator
Generic Part Name
Get help to fix this fault by requesting a quote