10.01.20

Massey Ferguson 10.01.20 – Air Conditioning Module (AIRCON): Issue With Air Circulation Flap Motors (AIRCON)

Issue description

Malfunction in the actuator motor responsible for opening and closing the air recirculation flap within the cab's HVAC system, preventing the system from properly regulating fresh versus recirculated air.

Applies to these machines

  • 7724S
  • 5712SL
  • 7722
  • 7722S
  • 5713SL
  • 7720S
  • 7716
  • 7718
  • T4
  • 7715
  • 5710SL
  • 7726
  • 7726S
  • 5711SL
  • 7718S
  • 7719
  • 7714
  • 7716S
  • 7720
  • Tier 4 (2015-2021)
  • 7715S
  • 7724
  • 4707
  • 4708
  • 4709
  • 4710
  • 5608
  • 5609
  • 5610
  • 5611
  • 5612
  • 5613
  • 7614
  • 7615
  • 7616
  • 7618
  • 7619
  • 7620
  • 7622
  • 7624
  • 7626

Check the cause

  1. Wiring and Voltage Check: Use a multi-meter to verify that proper voltage is reaching the flap motor actuator. Inspect the machine's wiring harness for any damage, breaks, or pinched wires leading to the HVAC unit.

  2. Connection Inspection: Check the electrical connectors at the flap motor and the AIRCON module for corrosion, rust, or bad contacts. Clean or repair them if necessary.

  3. Panel and Sensor Verification: Ensure the issue is not originating from the control panel. Related codes (such as 10.00.16 for the temperature dial, 10.00.17 for the fan speed dial, or 10.00.18 for the cab temperature sensor) can sometimes cause the AIRCON module to send incorrect signals to the flap motors.

  4. Mechanical Binding: Manually inspect the air circulation flap to ensure it is not physically jammed by dirt, debris, or a broken linkage, which would cause the motor to over-amp and throw a fault.

Repair steps

  1. Power Down

    Turn off the tractor and disconnect the battery to prevent electrical shorts.

  2. Access the HVAC Unit

    Remove the necessary cab interior trim panels (often located in the cab roof or under the seat, depending on the specific tractor series) to gain access to the HVAC housing.

  3. Locate the Actuator

    Identify the air circulation flap motor (actuator) mounted on the side of the HVAC air distribution box.

  4. Disconnect

    Unplug the electrical wiring harness connector from the faulty flap motor.

  5. Remove the Motor

    Remove the mounting screws securing the actuator to the housing. Carefully pull the motor away, noting the position of the mechanical linkage/spline.

  6. Install the New Part

    Align the new actuator's linkage with the air circulation flap door. Secure it with the mounting screws.

  7. Reconnect and Test

    Plug the wiring harness back in. Reconnect the battery, turn on the ignition, and operate the HVAC controls (switching between fresh air and recirculation) to verify the flap opens and closes smoothly without binding.

  8. Reassemble

    Reinstall all cab trim panels.

Parts you might need

(4)
  • Heater Actuator / Flap Motor

    ACW0932930

    Common replacement for cab climate control actuators

  • AGCO Actuator Assembly

    ACP0738080
  • Actuator Assembly

    764805M92
  • Air Circulation Flap Motor / HVAC Blend Door Actuator

    Generic Part Name

Get help to fix this fault by requesting a quote