Massey Ferguson 10.03.02 – AIRCON: Air Conditioning Vent Temperature Sensor Short Circuit
Issue description
The system has detected a short circuit in the vent temperature sensor circuit. This means the voltage signal returning to the controller is out of the expected range (typically shorted to ground or shorted to a voltage source), indicating that the sensor has failed internally or the wiring harness is compromised.
Applies to these machines
38 machines- 7724S
- 5712SL
- 7722
- 7722S
- 5713SL
- 7720S
- 7716
- 7718
- T4
- 7715
- 5710SL
- 7726
- 7726S
- 5711SL
- 7718S
- 7719
- 7714
- 7716S
- 7720
- Tier 4 (2015-2021)
- 7715S
- 7724
- 4700 Series
- 4707
- 4708
- 4709
- 4710
- 5600 Series
- 5608-5613
- 5700 Series
- 5710SL-5713SL
- 6600 Series
- 6700 Series
- 7600 Series
- 7614-7626
- 7700 Series
- 7714-7726S
- 8600 Series
Check the cause
Inspect the wiring harness leading from the AIRCON control module to the vent temperature sensor (located in the cab's HVAC ducting/evaporator housing). Look for pinched wires, chafing, or melted insulation that could cause a short to ground.
Disconnect the sensor and inspect the pins. Look for corrosion, moisture, or bent pins that could be bridging the circuit.
Measure the resistance (Ohms) across the sensor's terminals. A reading of near zero ohms confirms the sensor is internally shorted and must be replaced.
With the sensor disconnected, turn the key to the ON position and check the harness side for proper reference voltage (usually 5V) and ground. Check for continuity between the signal wire and ground to rule out a harness short.
Repair steps
Power Down
Turn off the tractor and disconnect the negative battery terminal to prevent electrical spikes.
Locate the Sensor
Access the HVAC unit inside the cab (often located under the seat, behind the seat, or in the roof console depending on the specific tractor model). Locate the vent temperature sensor plugged into the air ducting.
Remove the Sensor
Depress the locking tab on the electrical connector and unplug the harness. Twist or unclip the sensor to pull it out of the HVAC duct.
Install the New Part
Insert the replacement sensor into the duct housing and secure it. Reconnect the electrical harness until it clicks.
Reassemble and Reconnect
Reassemble any cab interior panels that were removed to access the HVAC unit. Reconnect the battery.
Clear Codes
Use the AGCO Electronic Diagnostic Tool (EDT) to clear the 10.03.02 / 10.00.02 fault code from the AIRCON module.
System Test
Start the tractor and engage the A/C. Verify that the automatic climate control regulates the vent temperature properly and that the fault code does not return.
Parts you might need
(4)Air Temperature Sensor
ACW0170190fits various MF & Challenger models
Evaporator Temperature Sensor
F931812140360Temperature Sensor
3907313M1common on 5000/6000/7000 series
AP Air Temperature Sensor
14-1136Aftermarket Alternative; Direct replacement for Massey Ferguson / Valtra A/C temperature sensors
Get help to fix this fault by requesting a quote