Massey Ferguson 10.03.09 – AIRCON: Air Conditioning Evaporator Temperature Sensor Open Circuit

Issue description

The control module is not detecting a continuous electrical path through the evaporator temperature sensor, which usually indicates a broken wire, a disconnected plug, or a completely failed sensor. As a safety consequence to prevent the evaporator core from freezing over, the air conditioning system is automatically turned off and cooling is disabled.

Applies to these machines

  • 7724S
  • 5712SL
  • 7722
  • 7722S
  • 5713SL
  • 7720S
  • 7716
  • 7718
  • T4
  • 7715
  • 5710SL
  • 7726
  • 7726S
  • 5711SL
  • 7718S
  • 7719
  • 7714
  • 7716S
  • 7720
  • Tier 4 (2015-2021)
  • 7715S
  • 7724
  • 4700 series
  • 5700 series
  • 6700 series
  • 4707
  • 4710
  • 6713
  • 5600 series
  • 5608 through 5613
  • 7600 series
  • 7700 series
  • 7614 through 7626
  • 7714 through 7726S
  • 8600 series
  • WR9950
  • WR9960
  • WR9970
  • WR9980

Check the cause

  1. Visually inspect the wiring harness leading to the evaporator temperature sensor for chafed wires, rodent damage, or a disconnected plug.

  2. Inspect the sensor connectors and the AIRCON module pins for corrosion, moisture, or backed-out pins.

  3. Unplug the sensor and measure resistance across its terminals using a multimeter. Infinite resistance (OL) indicates a failed sensor, while a normal thermistor value (kOhm range) indicates a wiring harness fault.

  4. Use the AGCO Electronic Diagnostic Tool (EDT) to monitor the live signal accuracy of the sensor while wiggling the wiring.

  5. Inspect the evaporator core for packed dirt and mud, cleaning it to ensure accurate temperature readings once repaired.

Repair steps

  1. Access the HVAC Unit

    Locate the HVAC housing. Depending on the tractor model, this is typically located either in the cab roof (headliner removal required) or under the cab seat.

  2. Locate the Sensor

    Find the evaporator temperature sensor. It is a probe-style sensor that is physically inserted directly into the fins of the evaporator core.

  3. Remove the Faulty Sensor

    Disconnect the electrical pigtail connector. Carefully pull the sensor probe straight out of the evaporator fins.

  4. Install the New Sensor

    Gently insert the new temperature sensor probe into the exact same location in the evaporator fins. Ensure it is seated deeply enough to accurately measure the core temperature without puncturing a refrigerant tube.

  5. Reconnect and Reassemble

    Plug the electrical connector back in. Reassemble the HVAC housing and cab interior panels.

  6. Clear Codes

    Turn the ignition on. The code may move from 'Active' to 'Stored' automatically once the circuit is restored. If the AC compressor does not engage, use the AGCO EDT to clear the stored fault codes.

Parts you might need

(5)
  • Air Conditioning Evaporator Temperature Sensor / Thermostat Sensor

    ACW0170190

    Widely used across Massey Ferguson, Fendt, Valtra, and Caterpillar applications

  • Air Conditioning Evaporator Temperature Sensor / Thermostat Sensor

    3907313M1

    Used on various Massey Ferguson models including 3000, 4200, 4300, 6100, and 6200 series

  • Air Conditioning Evaporator Temperature Sensor / Thermostat Sensor

    F530811140080

    Alternative AGCO/Fendt Part Number (Cross-references to ACW0170190)

  • Air Conditioning Evaporator Temperature Sensor / Thermostat Sensor

    220-507

    Aftermarket Option by AP Air Inc. (replaces 3907313M1)

  • Air Conditioning Evaporator Temperature Sensor / Thermostat Sensor

    220-474

    Aftermarket Option by AP Air Inc.

Get help to fix this fault by requesting a quote

Browse other Massey Ferguson codes