Massey Ferguson 10.03.29 – Air Conditioning Module (AIRCON): Issue With Voltage To Air Conditioning Module (AIRCON)
Issue description
The supply voltage signal reaching the module is higher than the maximum allowed value (overvoltage). To protect the circuitry, the control unit is automatically deactivated, which will cause the cab air conditioning and climate control functions to stop working.
Applies to these machines
36 machines- 7724S
- 5712SL
- 7722
- 7722S
- 5713SL
- 7720S
- 7716
- 7718
- T4
- 7715
- 5710SL
- 7726
- 7726S
- 5711SL
- 7718S
- 7719
- 7714
- 7716S
- 7720
- Tier 4 (2015-2021)
- 7715S
- 7724
- 4700 Series
- 4707
- 4708
- 4709
- 4710
- 5600 Series
- 5700SL Series
- 5608–5613
- 5710SL–5713SL
- 7600 Series
- 7700 Series
- 7614–7626
- 7714–7726
- 8600 Series
Check the cause
Test system charging voltage: Start the tractor and measure voltage across the battery terminals (should be 13.5V-14.5V; above 15V indicates an overcharging alternator).
Check module supply voltage: Back-probe the power supply pins at the back of the AIRCON module and compare this reading to the battery voltage.
Inspect wiring harness: Check the cab wiring harness for chafing or melting that could cause a short-to-power.
Check grounds: Verify that the cab ground strap and the AIRCON module ground wires are clean and tight.
Repair steps
Disconnect Power
Turn off the ignition and disconnect the negative battery cable to prevent electrical shorts during repair.
Address the Alternator (If Overcharging)
If your diagnostic checks revealed system-wide overvoltage, remove the drive belt and replace the alternator (or just the voltage regulator, if serviceable on your specific engine).
Repair Wiring (If Shorted)
If the alternator is fine but the module connector shows overvoltage, trace the harness back to the fuse panel. Repair any damaged wires using heat-shrink butt connectors and re-loom the harness.
Replace the AIRCON Module (If Internally Faulty)
If the supply voltage at the connector is perfectly normal (approx. 12-14V) but the module still throws code 10.03.29 and shuts down, the module's internal voltage sensing circuit has failed. Remove the trim surrounding the climate control panel, unscrew the retaining screws holding the module in the console, disconnect the electrical pigtails from the rear of the unit, plug in the new OEM control module and reinstall the trim.
Clear Codes
Reconnect the battery, turn the key to the ON position, and use a diagnostic scan tool to clear the inactive fault codes. Start the tractor and test the A/C blower and compressor engagement.
Parts you might need
(7)Ventilation/Air Conditioning Control Panel
ACW2146360Common on 3600 series and similar cabs.
Ventilation/Air Conditioning Control Panel
VA208730Cross-reference for ACW2146360
Ventilation/Air Conditioning Control Panel
3786659M2Cross-reference for ACW2146360
Ventilation/Air Conditioning Control Panel
3786659M3Cross-reference for ACW2146360
Control Panel Heating/AC Unit
V36519900AGCO Parts Control Panel Heating/AC Unit
A/C Control Unit
3907312M3Fits 8000 series
Alternator / Voltage Regulator
Exact OEM part number will depend entirely on the engine model fitted to your specific tractor
Get help to fix this fault by requesting a quote