10.X.23

Massey Ferguson 10.X.23 – AC Module (AIRCON): Optional Cab Extra Fan Relay Signal From AC Module (AIRCON)

Issue description

Communication or electrical circuit failure regarding the signal sent from the Air Conditioning control module to the relay that powers the optional extra cab fan.

Applies to these machines

  • 7724S
  • 5712SL
  • 7722
  • 7722S
  • 5713SL
  • 7720S
  • 7716
  • 7718
  • T4
  • 7715
  • 5710SL
  • 7726
  • 7726S
  • 5711SL
  • 7718S
  • 7719
  • 7714
  • 7716S
  • 7720
  • Tier 4 (2015-2021)
  • 7715S
  • 7724
  • 4707
  • 4708
  • 4709
  • 4710
  • 5608
  • 5609
  • 5610
  • 5611
  • 5612
  • 5613
  • 7614
  • 7615
  • 7616
  • 7618
  • 7619
  • 7620
  • 7622
  • 7624
  • 7626

Check the cause

  1. Verify the optional cab extra fan relay in the cab roof or main fuse/relay panel for continuity and ensure it is not stuck open or closed

  2. Inspect the wiring harness and connections between the AC Module (AIRCON) and the extra cab fan relay for chafed wires, loose pins, or corrosion

  3. Test the AC Module output to verify it is sending the voltage signal to the relay when the extra fan is commanded on

Repair steps

  1. Replace relay

    If the relay is faulty, replace it.

  2. Repair wiring harness

    If the wiring is damaged, repair the harness.

  3. Reprogram or replace AC module

    If the module fails to send a signal despite good inputs, the AC module itself may require reprogramming or replacement.

Parts you might need

(3)
  • Relay

    4349213M1

    12V, 120A Relay (Commonly used for high-draw cab components)

  • Relay

    3901509M1

    12V Relay (Engine electrics and cab instruments). Alternate part number: ACX3458080

  • 12 Volt, 5-Terminal 40 Amp Relay

    550-2602

    Generic Alternative (AP Air)

Get help to fix this fault by requesting a quote